WEG CFW100 Guía De Instalación, Configuración Y Operación página 4

Hmi remota serial
Ocultar thumbs Ver también para CFW100:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5 CONFIGURATIONS
It may be mounted outside the inverter on the panel
door
(figure
For connections that require distances over 3 m,
use connection of the remote serial HMI via RS485
interface connection (see
external power supply (see
When the remote serial HMI is connected to the
inverter, the inverter HMI only shows what is being
displayed on the remote serial HMI, and no changes
can be made on the inverter HMI.
Table 1: Signals of the connector for distance over 3 m
KHMIR Module
Terminal
Signal
1
RS485 - B
2
RS485 - A
3
4
5
+12 V
ATTENTION!
It is not allowed using simultaneously the
mini USB cable and the long cable over 3m.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
A.2) or command panel.
Connector
RS485 Module
Terminal
6
7
0 V
8
-
9
10
Remote Serial HMI
figure
A.3) and use an
table
1).
Description
Signal
RS485 - B
(Terminal B)
RS485 - A
(Terminal A)
External supply
0 V
(Reference 0 V)
Grounding
PE
Connection
External supply
-
(12 Vdc @
RS485
RS485
200 mA)