4600 Cam Parameters - Atlanta Attachment Company 4600 Manual Técnico & Lista De Partes

Tabla de contenido

Publicidad

Technical Manual & Parts Lists

4600 Cam Parameters

Before Programming, Perform a Master Reset of Parameters (See Below)
PARAMETER
RANGE
290
026
0-5
111
400-9900 rpm
119
1-3
161
0-1
220
1-55
240
0-55
270
0-5
272
015-9999
436
401
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off, Stop at needle down.
LED 6: On, Stop at needle up.
LED 7: Off
LED 8: Off
11
VALUE
0
Mode of operation. MUST SET THIS PARAMETER FIRST!
0
F-026=0 to disable the EB401 selection after power on.
1800
Maximum speed when "129" is 0, 1, or 2.
1
Linear acceleration
0=CW
Motor rotation
5
Acceleration
6
DISABLE CAM WITH N.O. SWITCH
5
External handwheel sensor configuration. 5=none
1000
Drive ratio between motor pulley and handwheel pulley.
Must use code "5913". This disables an input that was causing box to
0
reset itself.
0
1
Change 401 from 0 to 1 to save all parameters
Programming Instructions:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" once and "4.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E"
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.
DESCRIPTION

Publicidad

Tabla de contenido
loading

Tabla de contenido