4600 Puller Parameters

Before Programming, Perform a Master Reset of Parameters (See Below)
PARAMETER
RANGE
290
026
0-5
110
70-390
111
400-9900
119
1-3
153
0-50
161
0-1
220
1-55
270
0-5
272
015-9999
436
401
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off, Stop at needle Down
LED 6: On, Stop at needle Up
LED 7: Off
LED 8: Off
VALUE
0
Mode of operation. MUST SET THIS PARAMETER FIRST!
0
F-026=0 to disable the EB401 selection after power on.
70
Minimum speed (Positioning)
800
Maximum speed when "129" is 0, 1, or 2. **
1
Linear acceleration
35
Braking power at standstill
0-CW
Motor rotation for worm drive pullers
1
Acceleration
5
No handwheel sensor
Drive ratio for worm drive pullers. (current model)
1566
(Older belt drive pullers should be set on 1000)
The smaller the number the higher the speed
Must use code "5913". This disables an input that was causing box to
0
reset itself.
0
1
Change 401 from 0 to 1 to save all parameters
Programming Instructions:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" once and "4.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E"
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.
With sewing speed of 3000 and these par = 7.5 SPI
Make all puller speed adj with par 272 to maintain H/L speed sync
Increase Par 272 to increase SPI, decrease to Decrease SPI
4600 PARAMETER SETTINGS FOR PULLER MOTOR