Set Lcd Display Contrast; Maintenance; Battery Replacement; Troubleshoot - Bresser Tuya Smart Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SET LCD DISPLAY CONTRAST

In normal mode, press [
or wall mounted .

MAINTENANCE

BATTERY REPLACEMENT

When low battery indicator "
the current channel sensor battery power give wireless sensor shown is low respectively . Please
replace with new batteries .

TROUBLESHOOT

Problems
Indoor wireless
sensor is intermittent
or no connection
No WI-FI connection
Temperature or
humidity not accurate

SPECIFICATIONS

CONSOLE

General Specification

Dimensions (W x H x D)
Weight
Main power
Backup battery
Operating temperature range
Operating Humidity range
Support sensors
RF frequency
(Depend on country version)
Time Related Function Specification
Time display
Hour format
Date display
Time synchronize method
Weekday languages
In Temperature
Temperature unit
Accuracy
Resolution
/ CAL ] key to adjust LCD contrast for best viewing on table stand
" is displayed in CH section of the LCD display, it indicates that
Solution
1 . Make sure the sensor is within the transmission range
2 . Make sure the channel displayed match to the channel selection
on sensor
3 . If it still not work, reset the sensor and resynchronize with console .
1 . Check for WI-FI symbol on the display, it should be alway on .
2 . Make sure you connect to 2 .4G band but not 5G band of your WI-
FI router .
1 . Do not place your console or sensor close to the heat source
2 . If the sensor still not accurate adjust the value in calibration mode .
130 x 112 x 27 .5mm (5 .1 x 4 .4 x 1 .1 in)
220g (with batteries)
DC 5V, 1A adaptor
CR2032
-5˚C ~ 50˚C
10~90% RH
- 1 Wireless Thermo-hygro sensors (included)
- Support Up to 7 Wireless Thermo-hygro sensors (optional)
868Mhz (EU or UK version) / 915Mhz (US version) / 917Mhz
(AU version)
HH: MM
12hr AM / PM or 24 hr
DD / MM or MM / DD
Through the server to get the local time of the console location
EN / DE / FR / ES / IT / NL / RU
°C and °F
<0°C or >40°C ± 2°C (<32°F or >104°F ± 3 .6°F)
0~40°C ±1°C (32~104°F ± 1 .8°F)
°C / °F (1 decimal place)
35
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

7006300

Tabla de contenido