Intermatable and compatible with competitive same nose cam-type products - can be retrofitted to existing locations and power distribution systems.
Shatter and crack proof - high durometer thermoplastic elastomer (TPE) sleeve.
Color coded insulating sleeves - fast and easy phase identification.
Self-compensating for wear - slit and cam in male contact provide spring action for longer usage.
Fast connect/disconnect - twist and pull provided by double cam male and guide boss in female.
High conductivity - positive, vibration proof connection provided by double cam design.
Wide variety of applications - usable with a wide range of cable sizes and amperage ratings.
The 16 and 18 Series meet NEC Code, are UL listed and CSA Certified.
The 16 Series is rainproof - NEMA Type 3R enclosure rating for outdoor use.
• (1) Razor Cutting Blade
• (1) Pliers
• (1) Allen Wrench
• (1) Wire Cutter
• (1 or 2) Copper Shim(s)*†
• (2) Hex Head Socket Set Screw(s)*†
* Provided
†Depending on model
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH ELECTRICAL CODES AND REGULATIONS.
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.
WARNING:
USE "CU" CABLE ONLY. DO NOT EXCEED RATED CABLE AMPACITY FOR CORRESPONDING CABLE SIZE. ACCEPTABLE CORD TYPES INCLUDE; SC, SCE, SCT, OR TYPE "W".
CAUTION:
FEMALE CONTACTS FOR TAPER NOSE AND BALL NOSE DEVICES ARE NOT INTERCHANGABLE. TAPER NOSE ASSEMBLIES WILL NOT MATE PROPERLY WITH BALL NOSE ASSEMBLIES.
NOTE:
USE AMPACITY CHART FOR CORRECT CABLE SIZE APPLICATION.
TO WIRE DOUBLE SET SCREW VERSIONS:
WARNING:
1.
TO AVOID FIRE, SHOCK OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
2.
Strip approx. 1-7/16" of the jacket off the cable end (refer to Figures 1A). Wrap 1 or 2 copper shims around the exposed wire depending on your cable size.
NOTE: Wrap the center of the strain relief wire around the cable jacket between 3/8" and 1/2" from the end of the jacket and tighten by twisting with pliers.
3.
Bend the wire so that it rests flat against the shim making sure to squeeze the twisted portion tightly against the cable jacket.
4.
Cut the ends of the strain relief wire flush with the front end of the shim. Once secured, the strain relief wire will prevent the cable jacket from pulling away from the connector.
5.
Insert the exposed cable all the way into the contact with the strain relief wire opposite the hex socket set screw holes. Using an Allen wrench, tighten the 1/2-20 set screws to 120 in.-lbs. of torque, ensuring that they are firmly secure.
TO MOUNT PANEL RECEPTACLES:
1.
Prepare panel per Cutout Drawing provided below.
2.
Attach receptacle to panel using four (4) #10-24 fasteners with nuts and lock washers (not provided).
TO WIRE THREADED STUD VERSIONS:
1.
Determine correct size cable using Allowable Device Ampacity Chart. Determine correct lug based on cable size (not provided).
2.
Prepare cable end and insert and crimp cable into lug per manufacturer's requirements.
3.
Attach lug to threaded stud using ½" flat washer and ½-13 UNC hex nut (not provided). Tighten nut to 49 ft.lbs.
Figure 1 / Figura 1
16/18 Series Male and Female - Set Screw 1/0 to 4/0
Mâles et femelles de série 16/18 – Vis de fixation (calibres 1/0 à 4/0)
Macho y Hembra Series 16/18 – Juego de Tornillos 1/0 a 4/0
Set Screws
Vis hexagonales
Tornillos
Set Screws
Vis hexagonales
Tornillos
Set Screws
Vis hexagonales
Tornillos
Set Screws
Vis hexagonales
Tornillos
Allowable Device Ampacity Chart
Tableau des courants admissibles
Cuadro de amperaje permitido para el producto
Cable Size AWG
Calibre de Câble (AWG)
Câble à isolant résistant à 75° C
Tamaño del Câble (AWG)
#2
#1
1/0
2/0
3/0
4/0
NOTE: In open air, based on ambient temperature of 30° C. (86° F.)
REMARQUE : à l'air libre et à une température ambiante 30° C (86° F)
NOTA: Al aire libre, basado en temperatura de ambiente de 30° C (86° F)
16 Series Taper Nose In-Line Panel Receptacles
Rated: 600V, up to 400A continuous current using 4/0 cable with 90° C insulation
18 Series Ball Nose In-Line Panel Receptacles
Rated: 600V, up to 400A continuous current using 4/0 cable with 90° C insulation
• (1) Strain Relief Wire*†
Panel / Panneau / Panel
Male
mâle
macho
16 SERIES
Female
femelle
hembra
Panel / Panneau / Panel
Panel / Panneau / Panel
Male
mâle
macho
18 SERIES
Female
femelle
hembra
Panel / Panneau / Panel
75° C. Cable
Câble à isolant résistant à 90° C
Cable de 75° C.
Cable de 90° C.
170
195
230
265
310
360
FEATURES
ITEMS AND TOOLS NEEDED FOR ASSEMBLY
INSTALLATION INSTRUCTIONS
16/18 Series Male and Female - Threaded Stud #2 to 4/0
Mâles et femelles de série 16/18 – Goujon fileté (calibres no 2 à 4/0)
Macho y Hembra Series 16/18 – Borne Roscado # 2 a 4/0
Listed Compression Lug to suit cable size
Cosse à compression homologuée pour le calibre de câble
Terminal de compression listado acomoda tamaño del cable
Listed Compression Lug to suit cable size
Cosse à compression homologuée pour le calibre de câble
Terminal de compression listado acomoda tamaño del cable
Listed Compression Lug to suit cable size
Cosse à compression homologuée pour le calibre de câble
Terminal de compression listado acomoda tamaño del cable
Listed Compression Lug to suit cable size
Cosse à compression homologuée pour le calibre de câble
Terminal de compression listado acomoda tamaño del cable
90° C. Cable
190
220
260
300
350
400
Figure 2 / Figura 2
1/2-13 UNC HEX NUT
Écrou hexagonal UNC ½-13
Tuerca exagonal de ½-13 UNC
1/2 Diameter Washer
Rondelle d'un diamètre de ½ po (1,3 cm)
Arandela de ½" de diámetro
1/2 Diameter Washer
Rondelle d'un diamètre de ½ po (1,3 cm)
Arandela de ½" de diámetro
1/2-13 UNC HEX NUT
Écrou hexagonal UNC ½-13
Tuerca exagonal de ½-13 UNC
1/2-13 UNC HEX NUT
Écrou hexagonal UNC ½-13
Tuerca exagonal de ½-13 UNC
1/2 Diameter Washer
Rondelle d'un diamètre de ½ po (1,3 cm)
Arandela de ½" de diámetro
1/2 Diameter Washer
Rondelle d'un diamètre de ½ po (1,3 cm)
Arandela de ½" de diámetro
1/2-13 UNC HEX NUT
Écrou hexagonal UNC ½-13
Tuerca exagonal de ½-13 UNC
Cutout Drawing
Gabarit de découpage
Dibujo Precortado
SQUARE
1.50
CARRÉ
38.1
Cuadrado
0.75
19.1
0.75
19.1
PK-93680-10-02-0A
English
Panel
Panneau
Panel
Male
mâle
macho
16 SERIES
Female
femelle
hembra
Panel
Panneau
Panel
Panel
Panneau
Panel
Male
mâle
macho
18 SERIES
Female
femelle
hembra
Panel
Panneau
Panel
THRU
1.56
DIAM.
39.7
A través
THRU (4) PLACES
0.22
DIAM. (4 ENDROITS)
5.5
A través de 4 lugares

Publicidad

loading

Resumen de contenidos para Leviton 16 Serie

  • Página 1 16 Series Taper Nose In-Line Panel Receptacles Rated: 600V, up to 400A continuous current using 4/0 cable with 90° C insulation 18 Series Ball Nose In-Line Panel Receptacles Rated: 600V, up to 400A continuous current using 4/0 cable with 90° C insulation PK-93680-10-02-0A English FEATURES...
  • Página 2 There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.

Este manual también es adecuado para:

18 serie16r25-11g16r23-14g16r24-ug16r24-14w16r24-11e ... Mostrar todo