Appendix A - Specifications
• Size
Mount
Depth behind face plate 95mm max.
Display
• Colour
Black with texture on bezel.
• Backlighting
Red coloured diffused lighting for display.
• Water Integrity
Front will withstand direct water spray.
• Alarm
Audio and visual alarm indicates remaining
fuel total has dropped below a preset alarm
value.
• Flow
2.5 to 160 litres per hour
0.5 to 43 US gallons per hour
0.4 to 36 imperial gallons per hour
• Logs
Logs record fuel used up to 999 display units.
Total Log is saved in memory at power down.
Both Trip Log and Total Log can be reset via
the keypad.
Display is backlit for
Night Operation
Change Value Up
51mm diameter hole
3-character LCD
NAVMAN

Power
FLOW
Northstar
F210 Installation and Operation Manual
• Fuel Remaining
User enters a fuel value into memory via
the key pad. The quantity of fuel used is
automatically subtracted from this total. This
value remains in memory at power down.
• Operating Voltage
8 V DC to 16.5 V DC.
• Operating Temperature
0 to 50°C (32 to 122°F).
• Current Drain
70 mA max.
• RF Interference
<6 dB quieting on any marine radio channel
(with 3 dB gain antenna) within one metre
of the instrument. Complies with CE EMC
standards EN50081-1 and EN50082-1.