Failure Code - Peraqua 78508 Manual De Instalación Y Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46

Failure code

Failure
NO.
Failure description
code
1
EE 1
High pressure protection
2
EE 2
Low pressure protection
3
EE 3
Low water pressure protection
A.Single phase machine : failure connection due to
4
EE 4
loose wire terminal of PROT2 on the PC board
B.Three phase machine : 3 phase sequence protection
5
PP 1
Pool water temp sensor failure
6
PP 2
a. Heat only type : Exhaust temp sensor failure
7
PP 3
Heating coil pipe temp sensor failure
8
PP 4
Gas return temp sensor
9
PP 5
Air temp sensor
10
PP 6
Compressor exhaust overload protection
78508~78514:When
0℃,auto stop for protection (Not Failure )
11
PP 7
78739~78740:When
-7℃,auto stop for protection (Not Failure )
EE8/888
Communication Failures
12
/Messy
Code
the
temperature
the
temperature
29
Action
Contact your dealer.
Contact your dealer.
1. Check if there is no
water through the
machine; make sure the
pump is on.
2. contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Machine
Auto-protection
Contact your dealer.

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

785097851078511785127851378514 ... Mostrar todo

Tabla de contenido