Descargar Imprimir esta página

Temperature Protection; Short-Circuit Protection - Virax 252938 Manual De Utilización

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
Connection to the mains, start-up and use:
Before plugging-in the device, check the mains voltage and frequency values indicated on the nameplate. The
device is ready to operate as soon as the power lead is correctly plugged-in to the mains socket.
1) A steady red LED indicates that the device is ready to operate.
2) A flashing LED indicates that the device is shut down. There are 3 possible reasons for this:
a) TEMPERATURE PROTECTION:
If the temperature reaches 100°C, the device will shut down. After a maximum of 120 seconds, it will be ready to
operate once more.
b) OVERLOAD PROTECTION (device power limit):
If the device receives a charge of more than 45 A for longer than 10 seconds, it will shut down. It will restart after
10 seconds.
c) SHORT-CIRCUIT PROTECTION:
If the device is subjected to a surge of 65 A, it will shut down, then restart after 8 seconds. The power will be
switched off permanently after 3 short circuits. To resume working, unplug from the mains, wait for about 1 minute,
then reconnect.
Specifications and compatibility:
Voltage range
Rated power ( W )
Frequency
Protection class
Open circuit voltage
Output current
Operating
temperature
Cut-off temperature
Storage temperature
Mains adaptor 253026: Compatible with press fitting machine P20 ref. 253020 and P20+ ref. 253021
Mains adaptor 252938: Compatible with: - Press fitting machine M20+ ref. 253240 - 253250
Guarantee
The device carries a 2 year guarantee. Damage resulting from overload or incorrect operation are not covered.
A patent application covering mains adaptors 252938 / 253026 and their method of fabrication has been filed for
Europe.
252938
230 V ± 10% (207 V – 253 V)
450 W max.
50 Hz – 60 Hz
2
18 V max.
6 - 45 A
-20°C – +45°C
+ 100°C
-20°C + 60°C
- Eurostem®II bending machine ref. 2518 (battery-powered models)
253026
230 V ± 10% (207 V – 253 V)
400 W max.
50 Hz – 60 Hz
2
15 V max.
6 - 45 A
-20°C – +45°C
+ 100°C
-20°C + 60°C

Publicidad

loading

Este manual también es adecuado para:

253026