Options Affected By Regulations - Interlogix ATS000A-IP-SM Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
No.
Name
Function
5.
Test
Factory test mode
LEDs
In the following LED descriptions, a flash is defined as 250 ms
on and 250 ms off. Groups of flashes are separated by 1 s off.
MI_ST
The MI_ST LED (green) displays the status of the
communication interface to the panel.
Table 2: MI_ST LED status
Rate (±10%)
Duty cycle
Description
100%
Power on (in case none of the cases
below are valid)
0%
No power or power failure
25%
1 s
Initialization OK, waiting for
communication
50%
1 s
Everything OK, communication running
75%
500 ms
Hardware failure
50%
250 ms
Failure in communication, waiting for
reinitialization
CALL
The CALL LED (red) indicates status of the audio information
transmitted to the central station.
Table 3: CALL LED status
Rate (±10%)
Duty cycle
100%
0%
10%
1 s
50%
1 s
RSSI
The RSSI LED (green) indicates the field strength or signal
strength found by the GSM module. The number of flashes
indicates the level.
Table 4: RSSI LED status
Flashes
Description
Off
No field strength (no network detected)
1 to 4
Field strength indication from poor (1) to excellent (4)
NET
The NET LED (green) indicates the status of the network. The
meaning of the number of flashes is described in Table 5
below.
Table 5: NET LED status
Flashes
Description
Off
Not registered
On
Registered to home network
1
Registered to roaming network
4 / 40
Default value
Off
Description
Connected
Offline
Connecting
Ringing present
Flashes
Description
2
Searching network
3
Denied
4
Unknown
PSUE
The PSUE LED (red) indicates the status of the power supply.
Table 6: PSUE LED status
State
Description
Off
Power supply okay
On
Power supply problem
GPRS
The GPRS LED (yellow) indicates the status of the GPRS
communication.
Table 7: GPRS LED status
State
Description
Off
GPRS is not available
On
GPRS is available, connection established
Blink
GPRS is available, connection established, sending data
Flash
GPRS is available, connection not established
SIME
The SIME LED (red) indicates the status of the SIM card. The
meaning of the number of flashes is indicated in Table 8 below.
Table 8: SIME LED status
Flashes
Description
Off
Ready
1
PIN error
2
PUK error
3
PIN 2 error
4
PUK 2 error
5
SIM blocked from network
On
SIM not present

Options affected by regulations

The following settings are required for dial-up reporting
according to EN ATS 2:
Automatic test call period: 24 hours or shorter
The following settings are required for reporting via GPRS
according to EN ATS 5:
OH receiver: Linecut timeout 180 seconds
Advisor Advanced control panel: Polling period
120 seconds.
The following settings are required for reporting via GPRS
according to EN SP3:
OH receiver: Linecut timeout 30 minutes
Advisor Advanced control panel: Polling period
29 minutes.
P/N 146376999-5 (ML) • REV F • ISS 18SEP15

Publicidad

Tabla de contenido
loading

Tabla de contenido