I/O Expansion Module NPN/PNP Digital Inputs
1. With the inverter de-energized, remove the front
cover of the Inverter
2. Fit the accessory to be installed as shown in
A1 on page
3. Power up the inverter.
5 CONFIGURATIONS
The CFW100-IOD connections must be done to the
I/O expansion connector as per
The termination can be better viewed in
page
12.
Table 1: Signals of the I/O expansion connector
Connector
Description
6
DI5
Digital Input 5
7
DI6
Digital Input 6
8
DI7
Digital Input 7
9
DI8
Digital Input 8
10
GND
Reference 0 V –
Digital Inputs
NOTE!
The firmware version of the CFW100-IOD
accessory can be viewed in parameter P024
of the CFW100 inverter.
ATTENTION!
For the proper operation of the CFW100
inver ter with the CF W100-IOD module,
parameters P310, P311 and P312 must be
set with the factory default values. For further
details refer to the CFW100 programming
manual version V2.3X or above.
6 | CFW100
(Figure A1 on page
11.
4 isolated digital inputs
programmable (NPN or PNP).
Maximum input voltage of 30 Vdc.
PNP: Minimum input voltage for
activation 15 Vdc.
Input current: 11 mA.
Maximum input current: 20 mA.
Not interconnected to PE.
11).
Table 1 on page
Figure A2 on
Specifications
Figure
6.