Troubleshooting / alarms
Problem
The gate doesn't open or close
The gate opens/closes a short way,
and then stops
The remote control has limited range
and doesn't work while the gate is
moving.
The flashing light is not working
The "gate open" indicator light doesn't
work
Signalling and alarms
Y
G
Y
G
Y
R
R
R
If the problem persists, contact Ditec ENTREMATIC Technical Service, explaining the type of
alarm indicated by the LEDs.
No power
Short-circuited accessories
Contact Technical Service
Blown line fuse
Contact Technical Service
Release door microswitch open Check the position of the key.
Close the release door if it's open.
Contact Technical Service
Mechanical fault
Contact Technical Service
Faulty motor
Contact Technical Service
Faulty control panel
Contact Technical Service
Friction is present
Contact Technical Service
The batteries are running down. Replace them.
The lamp has blown. Replace it.
The wires are damaged or detached, or have short-circuited.
Contact Technical Service.
The lamp has blown. Replace it.
The wires are damaged or detached, or have short-circuited.
Contact Technical Service.
(for Ditec NEOS + only)
G
every 5s
flashing
G
in sync with
G
Y
every 10s
Y
steady on
R
steady on
R
every 1s
Possible cause
OFF
No power supply.
Mains power supply present, but gate
1 flash
stopped and waiting for commands. Any
external faults are not detected by the di-
agnostic LEDs.
Mains power supply present, normal
operation. Flashing LED in sync with
LAMPH
FLASHING LIGHT.
1 flash
No mains power supply (battery-powered
operation).
Maintenance request (alarm V0 on the
display)
Release door open
1 flash
Permanent alarm (see ALARMS and/or
TROUBLESHOOTING).