IMPORTANT REMARkS
TO REDUCE THE RISk OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARkS CARE-
FULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO
ALL THE PARAGRAPHS MARkED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORkING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS
OF ELECTRICAL EQUIPMENT" and must respect the local standards
and regulations in force. All materials used must be approved and
must suit the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally
qualified technicians. Before carrying out any cleaning or maintenance
operations make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it
has been made. "i.e. for the automation of one or two hinged gates".
The reversible 230Vac electromechanical operator 200/BL82 is
suitable for hinged gates up to ,2m in length and 00kg in weight.
• The unit may be fitted both to the right and to the left of the pas-
sageway.
• This product and all its relative components has been designed and
manufactured by Cardin Elettronica who have verified that the product
conforms in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper and
therefore dangerous.
The manufacturer accepts no liability for situations arising from the
use of an electrical installation which does not conform to the local
standards and regulations in force and in particular when the earthing
circuit is not efficient.
IMPORTANT! The geared motor is not fitted with a torque limiter.
Only use an electronic programmer which has a torque limiter
with maximum force at the head of the gate equal to 50N.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from
the main road to eliminate possible traffic disruptions.
2) The operator must be installed on the inside of the property and not
on the public side of the gate. The gates must not swing outwards
onto a public area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the gate
at all times.
5) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property
and one on the public side of the installation.
These signs must be indelible and not hidden by
any objects (such as tree branches, decorative
fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a gate installation. If possible
include this in the warning signs.
7) Whenever a fully open gate leaf comes within at least 500 mm of
a fixed structure the space must be protected by an anticrush
buffer.
IMPORTANT REMARkS
8) A correct earth connection is fundamental in order to guarantee the
electrical safety of the machine
9) If you have any questions about the safety of the gate operating
system, do not install the operator. Contact your dealer for assist-
ance.
TECHNICAL DESCRIPTION
- 230Vac motor mounted on a steel framework with an incorporated
overload protector
- Carter in extruded aluminium.
- Epicycloid reduction unit lubricated with permanently fluid grease.
- Operator arm in extruded aluminium.
- Joints in die cast aluminium.
- Gate attachments using adjustable, spherical joints.
- Motor support base in cast aluminium with stainless steel screws.
- Gate attachment bracket in spray-painted zinc plated steel.
ACCESSORIES
206/BL8BA - Standard articulated operator arm.
206/BL8BAS - Oversize articulated operator arm.
206/BL8BD - Straight operator arm.
980/xLSEC - Electric lock 2Vac.
INSTALLATION INSTRUCTIONS
The appliance is not suitable for continuous operation and must be
adjusted according to the technical data on page 20.
The minimum controls which may be installed are OPEN-STOP-
CLOSE, these controls must be installed in a location not accessible
to children.
Before starting with the installation of the system check that the struc-
ture which is to be automated is in good working order and respects
the local standards and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary
reinforce the structure) and that the hinges turn easily.
You are advised to grease all the moving parts using lubricants which
maintain unaltered friction characteristics over a period of time and are
suitable for temperatures of -20 to +70°C.
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire
distance between the gate and the support column measured
throughout the entire opening angle of the gate.
- make sure that the space between the bottom of the gate and
WARNING
the pavement never exceeds 30 mm throughout the entire opening
AUTOMATIC OPENING
angle of the gate.
kEEP CLEAR
• The surface of the gate must not feature openings which allow a
person's hand or foot to pass through.
• Check the exact positioning of the pivots and hinges, and their good
working order (the upper and lower hinges/pivots must be aligned
CHILDREN OR PETS MUST NOT
on the same axis).
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
• Work out the run of the cables according to the command and
control devices fitted and make sure the system conforms to the
local standard and regulations in force (see installation example fig.1
pag. 2).
• Check that the appliance is suitable for the size, weight and duty
cycle of the gate to which it is to be applied (see duty cycle on page
20)
9