IMPORTANT REMARKS
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS CARE-
FULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO
ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
equipment
All materials used must be approved and must suit the environment in which
the installation is situated.
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
for the automation of hinged gates
leaves.
product and all its relative components has been designed and manufactured
by Cardin Elettronica who have verified that the product conforms in every
aspect to the safety standards in force.
Any non authorised modifications are to be considered improper dangerous
and the complete responsibility of the installer.
Caution! mechanical stop buffers must be installed in both the open-
ing and closing positions (pos. 1, 2, 3, fig. 5).
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property and not on the
public side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be
situated at a height between 1,5 and 1,8 m in a position where the operator
can see the gate at all times.
5) At least two warning signs (similar to the example on the right)
should be placed, where they can be easily seen by the public,
in the area of the system of automatic operation. One inside
the property and one on the public side of the installation.
These signs must be indelible and not hidden by any
objects (such as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or
pets must not be allowed to play within the area of a gate
installation. If possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within 500 mm of a fixed struc-
ture the space must be protected by an anticrush buffer (fig. 1, detail 11).
8) If you have any questions about the safety of the gate operating system, do
not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
200/BL224ESB The operator is suitable for automating hinged gates (up to
2,2 m in length and 200 kg in weight per gate leaf) and consists of a compact
and tenacious appliance that is isolated inside a waterproof compartment and
is lubricated using permanently fluid grease.
If used with the maximum travel distance an opening angle of 90° and the
addition of an electric locking device, it can be used for gates up to 3,5 m in
length and 150 kg in weight.
carter.
28 Vdc with an incorporated encoder
containing cyclic train gears. Rotation is supported by a system of double
bearings.
extremely efficient under all working conditions and is protected by a solid
shock-proof plastic carter. Opening is obtained by inserting the key and
sliding the cover backwards.
special compartment fitted with a cable clamp and a protective cover.
ACCESSORIES
980/XLSE11C - Electric locking device 12 Vac
IMPORTANT REMARKS
installers of electrical
right and to the left of the passageway. This
WARNING
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
. NOT READING THESE IMPORTANT
USER INSTRUCTIONS
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred using
the supplied release key (see manual release page 4).
Periodically check the moving parts for wear and tear and grease if required,
paying particular attention to the never ending screw pos. 10 fig. 2, using
lubricants which maintain their friction levels unaltered throughout time and
are suitable for temperatures of -20 to +70°C. In case of failure or operational
anomalies switch off the power at the mains do not attempt to repair the
appliance yourself.
Periodically check the correct operation of all safety devices (photoelectric cells
etc.). Eventual repair work must be carried out by specialised personnel using
original spare parts. The appliance is not suitable for continuous operation and
must be adjusted according to the model (see technical data on page 48).
INSTALLATION INSTRUCTIONS
The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children and outside
the opening range of the gate.
Before starting the installation of the system check that the structure which
is to be automated is in good working order and respects the local standards
and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
- a minimum space of 30 mm must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the
pavement never exceeds 30 mm throughout the entire opening angle of
the gate.
hand or foot to pass through.
(the upper and lower hinges/pivots must be aligned on the same axis).
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example fig. 1 page 2).
the gate to which it is to be applied (see duty cycle on page 48).
ASSEMBLY PROCEDURE
The unit may be positioned either to the right or to the left of the passage-
way.
attachment bracket: complete rear attachment bracket (supplied with a
ferrule inserted at 145 mm) or a reduced bracket of 105 mm obtained by
transferring the rotation ferrule to the first hole (fig. 7a) and then cutting the
A
account the measurements "A" and "B", after having checked the position
of the gate hinge with respect to the column (measurement "C" fig. 4 page
4) according to the type of opening required.
Note: if the gate brackets are to be pre-installed (front and rear) without the
presence of the piston, you must also consult the indications in figure 9.
able safety rings will now be exposed)
the end of the closing direction travel distance and rotate the mechanical
7
9
2 page 3).
15
IMPORTANT REMARKS
15 mm from
"3" using the retaining pin "1" (fig.
-