Descargar Imprimir esta página

Panther PA-420C Manual De Instalación página 9

Ocultar thumbs Ver también para PA-420C:

Publicidad

Idiomas disponibles

Idiomas disponibles

long chirp and 2 Light flashes when the key is turned on indicates that you are in
feature selection of bank 2.
4. Press the pushbutton switch 1 time to access the first selection as shown below.
Use the button of the transmitter to change the feature selection or press the
pushbutton to advance to the next selectable feature.
Bank 2
Feature
1 Chirp/Flash
1stDoor Unlock
1S/1S
2nd Accy Lock
NA
3rd Accy. UL
On
4th Horn Chirp
10mS
5
th
Chp Del TX
NA
6th Park Lights
Normal
5. When finished setting the keyless/alarm selectable features, turn the ignition off then
on to advance to Bank 3, Remote Start Selectable Features.
1 Flash when the key transitions off, then 2 long chirps and 3 light flashes when the key
transitions on.
6. Press the pushbutton switch one time to access the first selection as shown below.
Use the button of the transmitter to change the feature selection or press the
pushbutton to advance to the next selectable feature.
Bank 3
Feature
1 Chirp/Flash
1 RF Start Chirp
Off
2 Run Time
5 Min.
3 Park Lights
On Steady
4 Input Check
Voltage
5 Voltage Level
> 0.5V B4 Start < 0.5V B4 Start
6 Ign. 2 Select
Off With Crank On With Crank Same As Accy
7 Diagnostics
Off
8 Crank Time
0.8Sec
9 Gas/Diesel
Gas
10 Grn/Blk (Aux O/P) Single Pulse
11 DBI Select
ADS
12 Time Start
2 Hours
Diagnostics:
Enter Bank 3 and turn on selectable feature # 7 as described in the feature selection and
setting section.
Exit the feature selection mode then press and hold the pushbutton valet/program switch
and then turn the ignition switch to the on position.
NOTE: Diagnostic mode is a temporary mode. Once you have accessed the diagnostic
mode, the unit will pause for two seconds then begin to flash the last stored shut
down code. This code will be displayed three times in succession, then the unit
will automatically exit the diagnostic mode.
The parking lights will flash a number of times indicating the reason for the last remote
start shutdown. The light flash indications are as follows:
1 Flash
Run timer expired
2 Flashes
Low or no tach signal (RPM)
3 Flashes
Positive inhibit wire activation
5 Flashes
RF shutdown signal received, or manual start trigger wire reactivated.
6 Flashes
High tach signal (RPM)
2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash
3.5 S/3.5S
1 S/Dbl 1 S.
Dbl 1/1 S
Off
16mS
30mS
40mS
NA
On 15 Sec W/UL
2 Chirp/Flash
3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash
On
10 Min.
15Min.
20 Min.
Flash
Tach
DBI Tach
Hybrid
On
1.0 Sec
1.5 Sec
2.0 Sec
Diesel 10
Diesel 15
Diesel 20
As D U/L Pulse
DBI
4 Hours
Page 9
Dbl 1/Dbl 1
1S L/350mS ul
50mS
3.0 Sec
4.0 Sec
128-9239
Default
1S
Off
16mS
Normal
Default
On
10 Min
Steady
Tach
> 0.5
On With Crank
Off
1.0 Sec
Gas
Single
ADS
4 Hours
9 of 24

Publicidad

loading