ENGLISH
4 Tool station DM 6700 digital control unit
- DM 6700 230V
- DM 6700 120V
- DM 6700 100V
This unit allows you to connect and work
simultaneously with all the tools.
You can connect this unit to all the tools of our
Advanced
series
corresponding stand, including the DR 5650
desoldering iron by adding the electric
desoldering pump MS 9004 Ref. 9004000 or the
air pressure desoldering system MS 9005 Ref.
9005000.
The station's components:
DM 6700 230V Ref. 6700200
- DM 6700 230V control unit
- Connection cable to mains
- Instructions manual
DM 6700 120V Ref. 6700100
- DM 6700 120V control unit
- Connection cable to mains
- Instructions manual
DM 6700 100V Ref. 6700110
- DM 6700 100V control unit
- Connection cable to mains
- Instructions manual
Kit DM 6700 4 tools 230V Ref. 6700230
- DM 6700 230V control unit
- MS 9004
electric desoldering pump
- 2245 handpiece
- DR 5650 desoldering iron
with the 5600-003 tip
- PA 4200 hot tweezers
- PA 1200 micro hot tweezers
- AD 8245 soldering iron stand
- DR 8500 desoldering iron stand Ref. 0788500
- PA 8120 hot tweezers stand
- PA 8110 hot tweezers stand
- 2245-003 cartridge
- 2245-271 cartridge (2 units)
- 1200-002 cartridge (2 units)
- Desoldering iron accessories
Speak to your distributor for more kits.
Ref. 6700200
Ref. 6700100
Ref. 6700110
but
always
using
Ref. 0269300
Ref. 0269320
Ref. 0269320
Ref. 6700200
Ref. 9004000
Ref. 2245000
Ref. 5650000
Ref. 4200000
Ref. 1200000
Ref. 0788245
Ref. 0748120
Ref. 0748110
Ref. 2245003
Ref. 2245271
Ref. 1200002
Ref. 0004166
Technical specifications
- Temperature selection from 90 to 450°C or
190 to 840°F (±5%).
- Power: 300W.
- Safety transformer, red separator and double
isolation, with an integrated temperature
protection fuse.
- DM 6700 230V control unit
its
Input: 230V 50Hz. Output: 24V.
- DM 6700 120V control unit
Input: 120V 60Hz. Output: 24V.
- DM 6700 100V control unit
Input: 100V 60Hz. Output: 24V.
- Total weight of unit: 6Kg (13,25lbs).
- ESD protected housing "skin effect".
Typical surface resistance: 10
square.
- Complies with CE standards on electrical
safety, electromagnetic compatibility and
antistatic protection.
- Equipotential connector and the tool tip are
connected to station mains ground supply for
ESD protection.
This product should not be thrown in the
garbadge.
2
Ref. 6700200
Ref. 6700100
Ref. 6700110
5
11
-10
Ohms/