2. AUX: if this is pressed for more than 1 second, it will auxiliary
output 1 on/off.
3. LIGHT: If this pressed for more than 1 second, it will turn
auxiliary output 2 on/off.
4. DOWN/DEF: if this pressed for more than 5 seconds, it will
turn manual defrosting on/off provided the evaporator
temperature is lower than the final programmed defrosting
temperature.
5. ON/OFF: if this id pressed for more than 5 seconds, it will turn
the apparatus on/off.
6. PRG/MUTE: in the event of an alarm: this mutes the sound alarm (buzzer) and deactivates the
alarm relay.
7. DOWN / DEF: if this is pressed for more than 5 seconds, it will turn manual defrosting on/off
provided the evaporator temperature is lower than the final programmed defrosting temperature.
8. SET: if this is pressed for more than 1 second, it will display and/or confirm the set point.
SIGNALS ON THE DISPLAY:
Icon
Funtion
COMPRESSOR
FAN
DEFROST
AUX
ALARM
CLOCK
LIGHT
ASSITANCE

Normal operation

ON
Compressor on
Fan on
Defrost in operation
AUXILIARY Auxiliary
output active
Delayed external alarm
(before "A7")
At least 1 timed defrost
has been configured
LIGHT auxiliary output
on
30
OFF
Destellando
Compressor
Compressor off
required
Fan off
Fan required
Defrost not in
Defrost
operation
required
AUXILIARY Auxiliary
output not active
Alarms in
No alarm present
normal
operation
No timed defrost is
present
Light auxiliary
output off
No malfunction
Malfunction
Start-up
ON if real-time
clock is present

Publicidad