Store and Recall
DG1000Z can store the current instrument state and user-defined arbitrary
waveform data in internal or external memory and recall them when needed.
DG1000Z also could interconnect with
TMC seamlessly and rebuilt and output the waveform data collected by the
oscilloscope losslessly.
Storage System
DG1000Z can store the current instrument state and user-defined arbitrary
waveform data in internal or external memory and recall them when needed.
DG1000Z provides an internal non-volatile memory (C Disk) and an external
memory (D Disk).
1. C Disk: provide 10 storage locations for state files and 10 storage locations for
arbitrary waveform files. Users can store instrument states and arbitrary
waveform files (created by users or downloaded via remote commands) to C
Disk and copy the files in USB storage device to C Disk.。
2. D Disk: available when USB storage device is detected by the USB Host
interface at the front panel.
Users can store state files and arbitrary waveform files to D Disk and the
number of the files can be stored is determined by the storage space of USB
storage device. The Txt files, Csv files and Bmp files stored in the USB storage
device can also be readed.
pulse Store (the key backlight goes on) at the front panel to enable the
Store/Recall function and open the Store/Recall interface as shown in the figure
below.