Attention:
This device shall only be connected to power
supplies compliant to EN60950-1, chapter 2.5
("limited power source").
Risk of damage to the device
Use the device only indoors and in dry
environments.
Do not expose it to dripping or splashing
water.
Do not let the contact areas of the board get
dusty and do not touch them with your bare
hands.
EC Declaration of Conformity
Siemens Security Products hereby declares that this
product is in compliance with the essential
requirements and other relevant provisions of
Directive 1999/5/EC on Radio and
Telecommunications Terminal Equipment (R&TTE)
and 2004/108/EC on Electromagnetic Compatibility
(EMC).
The EC Declaration of Conformity is available from
your Siemens sales office or:
Siemens AB, Security Products
Englundavägen 7
SE-171 24 Solna
Sweden
Product description
The SPCK620 is equipped with soft keys and large
graphical LCD for easy operation. The functionality
can be enhanced with key switch expander
SPCE110 or indication expander SPCE120.
The SPCK623 is equipped with a proximity card
reader (125 kHz EM 4102) for easy user access,
soft keys, large graphical LCD and voice
annunciation support. The functionality can be
enhanced with key switch expander SPCE110 or
indication expander SPCE120.
Product overview (Figure 1)
1
Lugs holding the PCB
2
Tamper switch
3
Card Reader (only SPCK 623)
4
Fixing screw for printed circuit board
5
Rotary switches
6
Breakout
7
Cable entry
8
Holes for fastening
9
Lugs
10
Corrugated-head screw for arcing contact
11
Screw terminal
12
Cable duct
Installation
Opening the housing
Loosen the screws by a couple of turns (Fig. 2).
Push the lugs downwards and slightly lift the
cover using a screwdriver (Fig. 2 item 1).
Lift the cover by approx. 1 cm and push it
upwards (Fig. 3).
Connecting cables
Insert the cable through the cable entry hole in the
base (Fig. 1 item 7).
If necessary, carefully remove the breakout pieces
(Fig. 1 item 6).
Connect the individual wires to the screw
terminals (see the following table and Fig. 6).
Attach the cable with a cable tie (Fig. 6).
See Fig. 1, item 11: Contact pins
Contact
Abbreviation Function
pin
1
LS -
Loudspeaker negative
(black cable)
2
LS +
Loudspeaker positive
(red cable)
3
1 A
X-BUS
4
1 B
X-BUS
5
2 A
X-BUS
6
2 B
X-BUS
7
0 V
Power supply negative
8
+ 12
Power supply positive
9
SCL
Not used
10
SDA
Not used
Mounting the base
Make sure to mount the unit only on surfaces
that are sufficiently hard and rigid.
Mark 3 holes for the fixing screws (Fig. 1 item 8)
and one for the safety screw (Fig. 1 item 10).
Drill the holes and screw the base.
Mounting the cover
Hook the top of the cover into the base and push
downward.
Push back the upper part of the housing.
 The two lugs on the base engage with the
corresponding recesses in the cover.
Tighten the two screws at the bottom of the unit
and seal them using the supplied seals (Fig. 5).

Installation instruction

Wiring the X-BUS interface
The X-BUS interface provides connection of
expanders and keypads to the SPC controller. The
X-BUS can be wired in a number of different
configurations depending on the installation
requirements.
NOTE: Maximum System cable length = number of
Expanders and Keypads in the system x maximum
distance for cable type.
Cable type
CQR standard alarm cable
UTP category: 5 (solid core)
Belden 9829
IYSTY 2 x 2 x 0.6 (min)
Fig. 7 shows the wiring of the X-BUS to an
expander/controller and the following
expander/controller in Spur Configuration. Terminals
3A/3B and 4A/4B (if available for this module) are
only used for using a branch wiring technique. If
using a Spur configuration, the last device is not
wired back to the controller.
See Fig. 7: Wiring of expanders
1 SPC controller
2 Previous expander
3 SPCK620/623
4 Next expander
Please refer to SPC Configuration Manual of
connected controller for further wiring instructions,
shielding, specifications and limitations.
X-BUS addressing
For addressing, reconfiguration, device location,
monitoring, editing of names, X-BUS type of
communication, failure timer please refer to SPC
Configuration Manual.
Technical data
128 x 64 pixels (approx. 6 x 20
LCD-display
characters)
SPCK620:
Max. 155 mA at 12 VDC
Operating
current
SPCK623:
Max. 230 mA at 12 VDC
SPCK620:
Quiescent
Max. 55 mA at 12 VDC
current
SPCK623:
Max. 110 mA at 12 VDC
Operating
9.5 – 14 VDC
voltage
X-BUS on RS-485 (307 kb/s)
Field bus
Tamper
Type B (per EN50131-3)
protection
Tamper
Front / back tamper
contact
SPCK623:
Card reader
Integrated (125kHz, EM 4102)
SPCK623:
Audio
Supported via integrated speaker
and microphone
Operating
5° ~ +40 °C
temperature
Relative
Max. 90 % (non-condensing)
humidity
Colour
RAL 9003 (signal white)
Mounting
Flat surface, wall-mounted
Housing
Plastic housing (Polycarbonate)
Dimensions
112 x 185 x 28 mm
(W x H x D)
Weight
0.38 kg
Housing
protection/IP
IP30
rating
Distance
200 m
400 m
400 m
400 m