Change Settings in the
Load working mode
display.
Press on the MENU
key for several seconds
until the numbers
flashes, you are in
setting mode for the:
H
The load can switched on and off by the
L
Load D2D
Load will switch on at sunset and switch off at sunrise .
L01-L23
The load output will switch on after sunset and switch off after 1-23
hours.
24H
The BlueSolar Charge Controller will continuously supply power to
your load.
Press on the MENU
key again and you go
to:
Press on the MENU
key again and you go
to:
Charge current display. It shows solar to battery current
and charge status.
Press MENU
to enter next display.
Load working mode.
The factory setting is 24H
Press MENU
to enter next display.
Load working mode setting.
See table below.
Load on/off switch
Load Setting: trigger value
(Solar Panel Voltage)
When the work mode is L01-
L23 the BlueSolar Charge
Controller will measure the
solar panel voltage to decide
whether its day or night to
switch load on or off. The
higher this value is the earlier it
switches on the load output.
The factory setting is 4V [8V]
16V
L01-L23 trigger delay value
(Seconds)
When the BlueSolar Charge
Controller measures a solar
panel voltage lower this value it
will delay for 10Sec and
measure again to make sure
night falls.
The factory setting is 10sec
.
7