Universal connection set (UA):
More information about Universal connection fitting type UA can be found at
www.gok-online.de/de/downloads/technische-dokumentation.
More information about compression fittings can be found at
www.gok-online.de/en/downloads/technical-
documentation/Assembly instructions - Compression fittings.
Installation position and mounting
Installation position vertical as a matter of principle,
•
filter cup
with filter element
Do not subject filters with plastic filter cups to ambient temperatures > +60°C, i.e. do
not install them near an uninsulated heat generator part or the exhaust pipe, and do
not install them above furnace doors which will be opened.
Risk of injuries due to blown-out metal chips!
Metal chips may cause eye injuries.
Wear safety goggles!
Malfunctions caused by residues! Proper functioning is not guaranteed.
Visually check that there are no metal chips or other residues in the connections!
It is important that metal chips or other residues are blown out!
Item No. 13 852 50 c
The female thread can also take the GOK universal
connection set type UA, which corresponds to a
compression joint type G acc. to prEN 12514-4:2009
Annex D.
Piping used:
Copper pipe with outer diameter 6, 8 or 10 mm, e.g.
acc. to EN 1057
The housing is made from a zinc die-cast alloy:
Do not use a conical pipe thread acc. to EN 10226-1.
Flexible pipe assembly
The following connections may be used in addition for
flexible oil lines and their pendant:
• cap nut G 3/8 with inside taper 60° pursuant to
prEN 12514-4 Appendix B
A reinforcement ring must be used with all thin-walled pipes and with
soft pipe materials.
Brass reinforcement rings may not come into contact with aluminium
pipe. Risk of corrosion!
at the bottom
9 / 14