SLIDING DOOR HARDWARE - WALL-MOuNt
1
FAStENING RECOMMENDAtIONS
• Track mounting fasteners are not supplied due to
differences in wall construction type and codes. Choose
track mounting fasteners appropriate for the structure.
Fasteners and the structural members they are attached
to must be capable of 75 lbs. shear and tension to
support the maximum rated load. Follow local building
codes for load-bearing items secured to the wall
type. Local code supersedes any of the following
recommendations.
2
AttACH WALL-MOuNt tRACK
• Track is designed to be secured on 16" centers or less (to line up with wood or steel framing structures) and within 8" of each end. For walls with
greater spacing between structural members, additional structure must be provided to achieve the required fastener spacing.
• Layout the location of the track on the wall. The door-closed side of the track should overlap the finished opening by 5/8" for a 1/2" door overlay.
Adjust the track overlap greater or lesser to achieve the desired door overlay. The track fastener mounting line is placed level at a height 3-1/4"
above the finished header.
• Find the locations of the structural wall framing members or solid anchor points and transfer to the track. If the mounting locations do not meet
the requirements above, additional structure must be provided to achieve the required fastener spacing.
NOTE: The track must be level in order for door to stay level.
• A shim board may be required to space track from wall to clear base or door molding and to provide a flat surface to mount track.
• Drill clearance holes for mounting fasteners using a 13/64" bit through track at the transferred locations. Locate hole centers on the groove
provided in the track mounting surface.
• Secure the track to the wall through the pre-drilled holes into the structural wall members using fasteners per section 1.
• Place hangers in wall track.
A
Wall construction shown is for reference only
B
16.0" fastener spacing maximum
C
8.0" max. unsecured either end
D
Horizontal track position relative to stud locations is determined by opening
location on wall and trim thickness. Position shown is for reference only.
E
Recommendation: Finished opening height = Door height + 3/8"
F
Recommendation: Finished opening width = Door width - 1"
G
Finished floor
H
Door height
I
May need to remove quarter round or shoe if large enough to interfere
with door operation
A
C
B
D
E
F
G
WOOD FRAMING:
• Use #10 Type A or Type AB thread pan head or hex-washer head.
Choose a length of screw so that 1" minimum is engaged into the
supporting wall structural member.
StEEL FRAMING:
• Use #10 Type AB thread pan head or hex-washer head. Screw length
must allow a minimum of three threads to protrude beyond inner wall
of framing.
MASONRY WALLS:
• Use appropriate anchors for the wall material. Anchors and substrate
must be able to support 75 lbs. minimum shear and tension loads.
3-1/4"
5/8"
3/8" Ref.
H
3-3/16"± 3/8"
I
K
J
J
3/8" ± 3/16" if > 9/16", must shim 1915 floor guide up to meet spacing.
K
Finish floor
L
Finish wall
M
Shim to match spacing of casing molding
N
Rough header
O
Finish header
P
1/16" nominal to hide hardware from opp. side. If needed, add 3/8" x 1-1/4"
stop to finish header to hide hardware in lower position.
Q
3/8" x 1-1/4" stop (not included /not required)
R
Door casing
#310374_A (0913)
Assembly
Instructions
L
M
3-1/4"
N
O
P
7/16"
1-3/8"
Q
1-3/4"
1/4"
R