4.2.6 DC current
Range
Resolution
2mA
0.001mA
20mA
0.01mA
200mA
10A
Overload protection:
mA socket: F 250mA H 250V fuse
10A socket : F10A H 250V fuse
Maximum input current:
mA output: 200mA DC
10A socket : 10A DC
When measuring current exceeding 2A, do not measure for more than 2 minutes
continuously. Wait 10 minutes to continue the measurement.
4.2.7 Battery test
Range
Resolution
12V
9V
1.5V
0.001V
Overload protection: F250mA H 250V fuse
0.1mA
10mA
0.01V
0.01V
Accuracy
±(0.8% of reading + 3 digits)
±(2.5% of reading + 3 digits)
Accuracy
±(0.8% of reading + 7 digits)
±(0.8% of reading + 7 digits)
±(3.0% of reading + 5 digits)