E. "Comfort" mode
In comfort mode, the temperature is set as per the digital
display setting, using increase and decrease keys .
F. "Night reduction" mode
In night reduction mode, the temperature is set as per the
digital display setting . This reduction brings considerable
energy savings, but at the same time allows to switch quick-
ly from reduction mode to comfort mode, ensuring optimum performance .
G. "Antifreeze" mode
In antifreeze mode, the thermostat keeps the 7°C safety
temperature to prevent that room temperature decreases
below zero degrees in the event of a prolonged absence .
H. Weekly programming
To access weekly programming, select the chronothermo-
stat mode, then press and hold "Function" key until "Pro"
is displayed .
The daily programme selection is displayed; use "
select the programme to change (d1 = Monday, d2 = Tuesday, . . . d7 =
Sunday) . Once the day has been selected, press "Function" key to ac-
cess the edit menu .
The display shows the day/programme and the time slot in programming;
press "
" key to set comfort mode in the time slot, or "
reduction mode in the selected time slot . Upon key release, the next time
slot is automatically selected .
At the end of daily programming, press "Function" key for two seconds to
go back to the daily programming selection . To finish programming, press
and hold "Function" key until "END" is displayed .
I. Clock programming
To access clock setting function, position to stand-by mode
as previously described, then press and hold "Function"
key until "Set" is displayed .
Use the keys to change the current time . Confirm the modification using
the function key .
L. Day programming
At the end of time programming, the selection of the day of
the week is enabled (d1 = Monday, d7 = Sunday) .
Cav. Ercole Cordivari
Use the keys to select the day of the week .
Amministratore unico
Confirm using "Function" key, the stand-by mode is automatically re-
stored .
Cav. Ercole Cordivari
Amministratore unico
1910000000242 - nv04
Cav. Ercole Cordivari
10 .Disposal
This management of the end of the life of a product allows us to preserve
our environment and to limit the use of natural resources .This symbol,
applied on the product, indicates the obligation to deliver the product at
the end of its working life to a special collection facility, in compliance with
Directive 2011/98/EU .
" or "
" keys to
" key to set
The Company Cordivari S .r .l . with registered office in Morro D'Oro (TE),
Zona Industriale Pagliare, hereby declares, under its own responsibility,
that the household electric radiators listed in par .1 comply with following
rules:
- CEI 61-150
- EN 60335-1 second edition
And therefore comply with essential requirements of European Directive
2014/35/CE and, when applicable, with 2014/30/CE
Morro D'Oro 14/12/2016
- 9 -
At the end of its working life, this equipment must be delivered
to the special collection facilities for recycling, since it is not a
standard domestic waste . In case of replacement, it can be
delivered to your distributor .
DECLARATION OF CONFORMITY
Cav. Ercole Cordivari
Amministratore unico
Cav. Ercole Cordivari
Amministratore unico
English