THE BUILDERS BOX SERIES HAS BEEN TESTED AND APPROVED IN ACCORDANCE WITH THE
MODEL
NUMBER
DESCRIPTION
33EB304GRS
39EB364GRS
45EB424GRS
THE INSTALLATION OF THE FIREPLACE UNIT MUST COMPLY WITH THE APPLICABLE
LOCAL AND/ OR NATIONAL ELECTRICAL CODES AND UTILITY REQUIREMENTS.
THIS INSTALLATION SHOULD BE ENTRUSTED TO DULY QUALIFIED
STEP - BY - STEP INSTALLATION OVERVIEW
1) Rough in framing following the
recommended dimensions. (see figure 1)
2) Allow at least 8" of service cable for
connecting power supply wire to junction
box on fireplace insert when installing
before finishing wall. Allow up to 4 feet of
service cable for connecting power supply
wire to junction box on fireplace insert
after finishing wall.
3) Remove the outer jacket and strip the
individual conductors ½" from end.
4) Loosen the screw securing the junction
box cover and remove the cover.
5) Place unit in position in the framed
opening, level with shims if necessary
!
If 120 volt operation is required, slide the voltage switch
and reconfigure the wiring accordingly (see figure 2).
LISTINGS AND CODE APPROVALS
CSA, No.220391, STANDARDS FOR FIXED AND LOCATION
DEDICATED ELECTRIC ROOM HEATERS.
MODEL SPECIFICATIONS
VOLTAGE
33" STANDARD
120/208/240
39" STANDARD
120/208/240
45" STANDARD
120/208/240
!!! WARNING !!!
PERSONNEL WHERE REQUIRED BY LAW.
(please read all instructions before installation)
!POWER SELECTION WARNING!
This unit is factory wired for 240 volt power supply.
Wires L1, L2, N & G are attached to the rear of
the junction box for easy access.
RATED POWER
WATTS
1440/2100/2800
1440/2100/2800
1440/2100/2800
and attach unit to frame using mounting
flanges provided ( see Section 3).
6) Wire a dedicated, properly fused circuit with
a 15 amp rating for the appropriate voltage
(120, 208/240). (See table above)
7) Install wall thermostat as outlined on
page 10 section E
8) Place all connections inside the junction
box. Secure the junction box cover on the
unit.
When installing a cable clamp make sure it
grips only the jacket of the service cable
and thermostat wire.
E-2
REMOTE
CONTROL
AMPS
YES
12.00/10.10/11.67
YES
12.00/10.10/11.67
YES
12.00/10.10/11.67
!