Festool SYS-PST 1500 Li HP Manual De Instrucciones Original página 22

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
English
LED 1 flashes green
1 > LED < 8 light up
green
All LEDs continuous­
ly light up green
1 > LED < 8 light up
green
Remaining LEDs
light up green in se­
quence from left to
right
7.5
Troubleshooting
1 > LED < 8 light up
yellow
1 > LED < 8 flash yel­
low
22
Ready for operation
SYS‑PST 1500 Li HP almost completely dis­
charged.
Charging (see section 7.2).
Ready for operation
Number of continuously lit green LEDs cor­
responds to state of charge.
Ready for operation
SYS‑PST 1500 Li HP is charged.
Not ready for operation, charging mode
SYS‑PST 1500 Li HP charging.
Number of lit green LEDs corresponds to
state of charge.
Overcurrent
AC output [1-3] has been deactivated.
Switch off (see section 7.3).
Wait for 10 seconds.
Switch on (see section 7.3).
Overheating
AC output [1-3] has been deactivated or
charging process has been interrupted.
In operating mode:
Switch off (see section 7.3).
Wait until SYS‑PST 1500 Li HP has
cooled down.
Switch on (see section 7.3).
If LEDs continue to flash yellow, switch
off again (see section 7.3) and leave to cool
down further.
In charging mode:
Wait until SYS‑PST 1500 Li HP has
cooled down. If necessary, open the