CAME ZD2 Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Activating the remote control
-Connect the antenna's RG58 cable to the apposite terminals.
-Lock the radiofrequency card into the electronic card
ries).
N.B.: the electronic card only recognises the radiofrequency card when the power is on.
Memorisation
CH1 = Channel for direct command to a function of the the gearmotor's card, ("open only / "open-close-invert" or "open-stop-close-stop"
command, depending on the choice made on DIP switches 2 and 3).
CH2 = Channel for direct command an accessory device connected to B1-B2.
A
-Keep the "CH1"
button on the electronic card pressed. The LED fl ashes.
-Press the transmitter button you wish to memorise. The LED will stay on to show memorisation has been successful.
-Repeat the points 1 and 2 procedures for the "CH2" button associating this to another button on the transmitter.
Programmation to save gate-run and decelerations adjustments
Do the adjustment by making the operator execute a complete opening/closing manoeuvre
The control board automatically registers the gate-run adjustments with opening and closing decelerations.
To save the adjustment, position dip 6 in ON
Re-position the dip in OFF
Note: you need to reposition the dip in OFF so to avoid that the reactivation of power supply after a blackout provokes a new adjustment
while executing the first manoeuvre.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
A
AFTER CUTTING OFF THE POWER SUPPLY (or after disconnecting the batte-
D
E
A
and press CH1 button
B
until the signalling led stays on.
B

Publicidad

Tabla de contenido
loading

Tabla de contenido