The Tare function resets the value displayed by the
product to zero. This function is obtained by pressing
the Tare button for 2 seconds (ref. E, fig 1).
GB
It is then possible to apply a force and display its net
value.
Pressing the Tare button switches from the net value to
the gross value.
Description of Figure 8.
Reference
A
Gross force
B
Net force
C
Application of a force = net force
D
1 press net force <> gross force
When the tare function is activated, a reduction
in force may cause the display to turn negative.

5.4.3. Peak load function

The peak load function is used to store the maximum
value reached when force is applied.
To activate the function, press the button T3 (ref. D,
fig 1). The "MAX" symbol appears and remains on the
display.
The value displayed is the maximum force applied.
To deactivate, press the button T3 once again.
Description of Figure 9
Reference
A
Measurement in progress
B
Activating the Peak Load function
The maximum value of the measurement
C
remains displayed
D
Deactivating the Peak Load Function
The tare function is accessible in peak load mode.

5.4.4. Change of units

See figure 10
Hold the button T3 (ref. D, fig. 1) pressed down to scroll
through the units (kg, daN, lbs), and release the button
T3 to select the unit.

5.4.5. Turning the product off

See figure 11
10
Description
Description
To turn the product off, press and hold the on/off button
for 2 seconds.
If there is no load variation, the product will turn
off automatically after 20 minutes.
On request, Tractel
can disable this function.
®

5.4.6. Overload

When the force applied on the sensor exceeds the
maximum capacity of the product by more than 10%
(e.g. 1 t loaded at 1.1 t) the integrated display shows the
overload status message "- HI -" shown below.
In case of overload, it is imperative to fully release
the force on the sensor and check that the product is
again showing zero.
If the product indicates a force value even when
it is not subjected to any force, it has been deformed
permanently. In that case, the product must absolutely be
checked by the manufacturer before continuing to use it.

5.5. Deinstallation

When deinstalling the product, make sure that all
tensile forces have been removed beforehand.
Clean the product and store it according to the sections
7.2.Other verifications and 8.Transport and storage

6. Prohibited uses

The following are forbidden:
• Using the product for commercial transactions.
• Using the product in a personnel lifting line without
first carrying out a specific risk analysis.
• Modifying the product.
• Using the product beyond its SWL with static or
dynamic forces.
• Arc welding with the product in the ground circuit.
• Exposing the product to any electric and/or
electromagnetic shock.
• Disassembling or opening the product.
• Using the product for operations other than those
described in this manual.

Publicidad