Wiring:
1. Connect the remote manual switch and inline fuse between
the battery and the UltimaSwitch.
2. The wiring connections should be made with water resistant
permanent terminals. Liquid electrical tape should be used to
coat the terminals. The mount connections should be above
the highest water level.
3. The Brown with White Tracer (+) UltimaSwitch wire should
be attached to the fused wire from the positive terminal.
4. The Brown relay UltimaSwitch wire to the Brown (+) pump
wire.
5. The Black (-) pump wire to the negative battery terminal.
6. 2 Way Dash Panel Switch Auto/On Operation. Connect
brown switch wire lead and brown positive (+) pump wire
lead to positive (+ ON position) of dash panel switch.
Connect brown with White Tracer switch wire lead to positive
(+) battery terminal (in line fuse required).
7. 2 Way Dash Panel Switch OFF/ON Operation. Connect
brown switch wire lead to brown positive (+) pump wire lead.
Connect brown with white tracer switch wire lead to positive
(+ On Position) of panel switch (Inline fuse required)
8. 3 Way Dash Panel Switch ON/OFF/Auto Operation. Connect
brown switch wire lead and brown positive (+) pump wire
lead to positive (+ ON Position) of dash panel switch.
Connect Brown with white tracer switch wire lead to positive
(+ Auto Position) of panel switch (Inline fuse required). Black
negative (-) wire lead from pump always to ground.
Original instructions
> English