4. When the tank pressure drops down to 145 psi, the control valve will close and the
engine will return to full speed. The compressor will resume pumping air into the
tank.
Do not alter pressure settings on control valve or governor setting on engine. If lower
pressures are required this should be accomplished with a separate pressure regulator
after the outlet valve. The compressor has a maximum operating pressure limit of
175 psi and should not be operated beyond this limit.

CRANKCASE BREATHER

During severe operating conditions or initial start-up, some oil may accumulate
at the crankcase breather opening. This is normal and will diminish as the pump
accumulates run time and the piston rings become fully seated.
DRAINING TANK
Condensate must be drained from the tank daily (see Figure 8).