Important Remarks; Electronic Programmer; Electrical Connection - Cardin YPR851BCC Manual Del Usuario

Programador electronico para el mando de bareras motorizadas en corriente continua
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

IMPORTANT REMARKS

READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY
PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
THESE IMPORTANT WARNINGS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
• Before commencing with the installation of this appliance make sure that you
have read the following instructions carefully.
In particular familiarise yourself with the safety devices required by the system,
only then will you be able to use them to great effect.
• Not all of the safety devices required by the local safety standards have been
taken into consideration in this manual.
The installer must therefore make sure that any eventual safety devices required
by the local standards and regulations have been installed both ahead of and
after the products described in this manual.
• These instructions are aimed at professionally qualified "installers of electrical
equipment" and must respect the local standards and regulations in force .
• This appliance must be used exclusively for the purpose for which it has been
made. "i.e. for the automation of gates and doors" Any non authorised modi-
fications are to be considered improper and therefore dangerous.
Attention! This electronic programmer can only be used
with motors of the Technocity by Cardin range of products
series "EL".

ELECTRONIC PROGRAMMER

Electronic programmer for a DC motor with an incorporated radio receiver card,
which allows the memorisation of 300 user codes (see "remote control" page
10). The 'rolling code' type decoder uses 433.92 MHz. series transmitters.
The travel speed is electronically controlled based on indications given by the
travel limits, starting slowly and increasing in speed; the speed is reduced
as it nears the completely closed/open position so as to enable a controlled
smooth stop.
Programming is carried out using two buttons and allows you to configure the
system and set the pause time.
The intervention of the anticrush/antidrag sensor during the closing and open-
ing stages causes travel direction inversion (if automatic reclosing has been
enabled).
If activated towards the end of the movement (almost closed) it will act as an
amperometrical travel limit.

ELECTRICAL CONNECTION

Open the "Wiring diagram". To make it easier to follow the instructions the
diagram has been placed on the inside of the last page of this manual.
Legend
B
Signal buzzer "via radio" mode
D
Seven segment display
F
,6A delayed fuse (230Vac 50-60 Hz power supply)
F2
A rapid action fuse (24V circuit )
F3
0A rapid action fuse (motor power supply)
J2
Enable transmitter memorisation via radio
(without opening the container)
L
LED power on
L2
LED transmitter code management
L3
LED manual operation
L4
LED inverting photocells activated
L5
LED opening travel limit activated
L6
LED closing travel limit activated
L7
LED stop button activated
L8
LED stop photocell activated
M Memory module (300 codes)
P
Programming button
P2
Selection button
P3
Transmitter code memorization button
P4
Transmitter code cancellation button
R
433 MHz radio frequency module
CN Secondary Faston connection 24Vac
CN2 Secondary Faston connection 20Vac
(V0:0Vac, V:5Vac, V2:33Vac)
CN3 Motor Faston connection
IMPORTANT REMARKS
Before connecting the appliance make sure that the voltage and frequency
rated on the data plate conform to those of the mains supply. An all pole
trip switch with at least 3mm between the contacts must be installed
between the unit and the mains supply.
• Connect the control and security device wires.
• Connect the power supply cable to the device.
• Do not use cables with aluminium conductors; do not solder the ends of
cables which are to be inserted into the binding posts; use cables which are
marked T min 85°C and are resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the wire and the
insulating sheath are tightly fastened (a plastic jubilee clip may be used).
Terminal board connection (pag. 28)
1-2-4-5 Common for all inputs and outputs
3
24Vac 7W in output, powering external devices
24Vac 0W in output warning lights
6
(intermittent or continuous activation)
7
TD (contact N.O.) dynamic button input "Open-Close"
8
TB (contact N.C.) stop button input (The opening of this contact inter-
rupts the cycle until a new movement command is given)
9-17
Common for all inputs and outputs
10
FCC (contact N.C.) closing travel limit switch
FCA (contact N.C.) opening travel limit switch
11
12
FTCI (contact N.C.) safety and control devices in input (photocells
invert the travel direction when an obstruction is detected) The opening
of this contact will provoke a travel direction inversion during closure
due to the cutting in of the safety device
13
FTCS (contact N.C.) safety and control devices in input (stop photo-
electric cells). The opening of this contact will block all movement, until
the obstruction has been removed, due to the safety device cutting in,
the door will then continue moving until it reaches a travel limit (only
in the automatic mode)
14
TC (contact N.O.) closing button input
TA (contact N.O.) opening button input
15
16
TAL (contact N.O.) closing button input (active when released)
18
Indicator light 24Vac 3W
230Vac 50-60 Hz output powering the toroidal transformer
19-20
21-22
Power supply 230Vac 50-60 Hz
23-24
230Vac 40W + 40W courtesy light output
25
Programmer earthing wire
26
Motor earth outputs
Outer conductor for radio receiver antenna.
27
28
Inner conductor
fitted use a coaxial type cable RG58 with an impedance of 50Ω)
NOTE: ALL UNUSED NC CONTACTS MUST BE JUMPED
Switch on the power and make sure that the red indicator LEDS are in the
following condition:
- L Power on LED
- L2 Transmitter programming LED
- L3 Manual mode LED
- L4 Safety LED for the inverting photoelectric cells
- L5 Opening direction travel limit LED
- L6 Closing direction travel limit LED
- L7 Safety LED for the stop button
- L8 Safety LED for the stop photoelectric cells
Check that the activation of the safety devices switches the corresponding
LEDS off.
If the power on LED doesn't light up check the condition of the fuses and the
power cable connection between binding posts "2" and "22" (pag. 28).
If one or more of the safety LEDS do not light up check the contacts of the
relative security devices and check that the unused safety device contacts
have been bridged.
7
IMPORTANT REMARKS
. NOT READING
for radio receiver antenna (if an external antenna is
on
off
off
"FTCI"
on
"FCA"
on
"FCC"
on
"TB"
on
"FTCS"
on

Publicidad

Tabla de contenido
loading

Productos relacionados para Cardin YPR851BCC

Este manual también es adecuado para:

El3024

Tabla de contenido