(Table 7) BURNER FEATURES (DE, AT, CH – KAT. II
)
II
2H3B/P
Gas type
Liquid gas LPG
(G30-G31)
Natural Methane gas
(G20)
Natural Methane gas
(G25)
Liquid gas LPG
(G30-G31)
Natural Methane gas
(G20)
Natural Methane gas
(G25)
WARNINGS
General
• Read the instructions carefully before installation, use and maintenance of the appliance.
• Installation must be carried out by qualified personnel following the manufacturer's instructions
in the specific manual.
• The appliance must only be used by trained personnel and only for the intended use.
• In the event of breakdown or malfunctioning, switch off the appliance and call in after sales
assistance only from an authorized centre.
• Use only original spare parts; otherwise no liability is accepted by the manufacturer.
• The appliance must not be washed with high pressure water sprays, neither must the openings or
be blocked.
ATTENTION! The manufacturer declines any liability for damage caused by wrong
installation, tampering, making unauthorized changes, improper use, poor maintenance,
installation of non-original spare parts, not observing local norms, incorrect use or not
observing the instructions in this booklet
For the installer
• The functioning of the appliance must be explained and shown to the user. After having ensured
that everything is clear, the instruction booklet must be handed over.
• The user must be informed that any building modification or restructuring that may in any way
modify the air supply necessary for combustion, makes it necessary to carry out another check of
the functionality of the appliance.
Nominal
Reduced
capacity
capacity [kW]
[kW]
FRYER BURNER ½ module
15.00
-
14.60
-
14.60
-
FRY TOP BURNER 1 module
15.00 x 2
-
14.60 x 2
-
14.60 x 2
-
Diameter of main
injectors
[1/100 mm]
[1/100 mm]
100
170
185
100 x 2
170 x 2
185 x 2
Pag. 43/87
By-Pass
Pilot injectors
diameter
[N° ]
-
30
-
51
-
51
-
30 x 2
-
51 x 2
-
51 x 2
,
2ELL3B/P
Air regulation
"x"
[mm]
Open
Open
Open
Open
Open