Descargar Imprimir esta página

VISUAL PLUS XPR EX5 Manual Del Usuario página 18

Publicidad

UK
PROGRAMMING FLOWCHART
Assign a
Change
User Code
Master code
Press (0)
Press (0)
+
Memory position
Memory
from 01 to 99
position (00)
Keypad
Proximity
Reader
Reader
Present Card/Tag
before the Reader*
Notes
Memory Position for User Code is always 2 digits
* no need to validate with A
Assign Examples
Ex.1: To assign User Code "12345" at Memory Position "5" and Relay 1 (2A) in Latch Mode assuming Master Code = 000
Press 000B + 0 + 05 + 12345 + A + 7 + 05 + 1 + A + 1 + 00 + A + B.
Ex. 2: To assign User Code "6789" at Memory Position "6" and Relay 2 that activates for 5 seconds assuming Master Code = 000
Press 000B + 0 + 06 + 6789 + A + 7 + 06 + 2 + A + 2 + 05 + A + B.
See: Assign a User code
Above
Warranty : VPC warrants it's products to be free from defects in material and workmanship for 24 months from the date of shipment. The product is to be installed in
accordance with VPC's instructions and the unit should not be modified or tampered with. VPC does not assume any responsibility for damages arising from misuse of the
product. VPC's sole responsibility is limited to the repair or replacement when the product is sent to VPC facility.
VPC, Av. du Congo 11, 1000 Brussels - Belgium
As per the European Directives 2002 / 95 / EC & 2002 / 96 / EC
This product is in compliance to the restriction of hazardous substance - ROHS under (Directive 2002 / 95 / EC) and this product should not
be disposed in the municipal waste stream but should be handed over to any designated collection facilities appointed by the government or
the local authorities to enable recovery & recycling as per weee (Directive 2002/96/EC). w.e.f 1st july'2006
www.visual-plus.com
Enter "Master Code" OR "000" (if first time use)
1 small beep + 1 long beep + Yellow LED is 'on'
Assign Output
Press (7)
+
+
Memory position from
(01 to 99)
+
Press (1) for Relay 1
And/Or
Press (2) for Relay 2
And/Or
Press (3) for Relay 3
And/Or
Press (4) for Relay 4
Enter new code
(1 to 8 digits)
See: Assign Output
above
Start
Validate by pressing (B)
No
Validation OK?
Yellow LED blinks rapidly
Yes
Set Output Timer
Pulsed Mode (01 to 99 sec):
Relay 1 : Press 1
Relay 2 : Press 2
Relay 3 : Press 3
Relay 4 : Press 4
+
01 to 99
Or
Latch Mode (ON/OFF):
Press (1) or (2) or (3) or (4)
+ (00)
Press A to validate
Validation
No
OK?
Yes
Press B (Yellow LED is 'off')
End
See: Set Output Timer
6
Multiple small beeps
+
Assign Relay to
Exit Button
Press (5) for PB1
Press (6) for PB2
Memory position
+
from (01 to 99)
Press (1) for Relay 1
And/Or
Press (2) for Relay 2
And/Or
Press (3) for Relay 3
And/Or
Press (4) for Relay 4
above
Delete
Delete
Single Code
All Codes
Press (9)
Press (8)
+
+
(99)
EX7

Publicidad

loading

Productos relacionados para VISUAL PLUS XPR EX5

Este manual también es adecuado para:

Xpr ex7