Textron Greenlee GT-55e Manual De Instrucciones página 14

Verificadores de tensión, continuidad y rotación de fase
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 65
Specifications and Accuracy (cont'd)
GT-55e (cont'd)
Rotary Field Indication
Voltage Range (LEDs): 100 V to 690 V
Frequency Range: 50 Hz to 60 Hz
Measurement Principle: Double-pole and firmly hold the
grip (L2)
GT-85e
Voltage Range: 6 V to 690 V AC/DC
Bargraph Resolution: ± 6, 12, 24, 36, 50, 120, 240, 400,
690 V
LCD Voltage Range: 10 V to 690 V AC/DC
LCD Resolution: 1 V
Accuracy: ± (3% reading + 2 V)
Voltage Detection: Automatic
Acoustic Signal Sound:
AC Voltage: Yes
– DC Voltage: Yes
Polarity Detection: Full range
Range Detection: Automatic
Response Time: < 0.1 s/BAR; < 2 s/reading
Frequency Range, DC: 45 Hz to 65 Hz
Automatic Load (RCD): Yes
Peak Current: Is < 0.2 A / Is (5 s) < 3.5 mA
Operation Time: ED (DT) = 30 s
Recovery Time: 10 min
Auto Power On: < 12 VAC/DC
Power Supply: 2 x 1.5 V Micro IEC LR03
Power Consumption: Max. 30 mA / approx. 250 MΩ
Single-pole Voltage Detection Test
Voltage Range: 100 V to 690 V AC
Frequency Range: 45 Hz to 65 Hz
Continuity Test
Threshold: < 200 kΩ
Test Current: < 20 µA
Overvoltage Protection: 690 V AC/DC
Rotary Field Indication
Voltage Range (LEDs): 100 V to 690 V
Frequency Range: 50 Hz to 60 Hz
Measurement Principle: Double-pole and firmly hold the
grip (L2)
Resistance Test
Resistance Range: 0 kΩ to 2 kΩ
Accuracy: ± (3% reading + 10 Ω)
Test Current: < 0.5 mA
14

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Greenlee gt-85e

Tabla de contenido