The Live Plug Connector applies the Genny signal to a live domestic
power socket and, via the domestic wiring system, to the service and
supply cable in the street.
Connect the Live Cable Connector to the Genny4 accessory socket
and the mains power socket, then switch the Genny4 and the power
socket on.
NOTE: The Live Plug Connector provides protection to 250V AC.
Service and Maintenance
The C.A.T4 and Genny4 are designed to require minimal
recalibration. However, as with all safety equipment, it is
recommended that they are serviced and have their calibration
validated at least once a year using Radiodetection approved test
equipment. Radiodetection accepts no responsibility for service,
calibration or repairs carried out by non-authorised persons.
To check when the C.A.T4 is next due to be calibrated, squeeze
the trigger, then press the depth button until 'C' (Configuration)
is displayed. The display will now automatically step through the
following information: 'S' (software version), 'F' (firmware version),
'D' (day), 'M' (month) and 'Y' (year).
e Ce rT
™
All C.A.T4 models feature eCert, which provides a thorough test of the
C.A.T4 locating circuitry, and supplies a Radiodetection Calibration
Certificate when a positive test result is obtained. To run an eCert test,
the C.A.T4 should be connected to an internet-enabled PC on which
the C.A.T Manager software is installed. Additional purchase may be
required, visit www.radiodetection.com or contact Radiodetection for
more details.
18
r e pLACI n G BATTe r I e s
Do not mix new and old batteries or different types of
batteries, as this may cause them to overheat.
C.A.T4
To replace batteries, open the access cover using
a screwdriver or coin. Use two LR20 (D-cell)
alkaline batteries or equivalent NiMH rechargeable
batteries.
Genny4
To replace batteries, open the access cover using
a screwdriver or coin. Use four LR20 (D-cell)
alkaline batteries.
pr od U CT s pe CI fI CATI on
Operating temperature range -20°C to +50°C (4°F to 122°F)
Environmental protection
IP54
Depth accuracy
Line: ± 5% tolerance from 0.1m (4")
to 3m (10ft)
Sonde: ± 5% tolerance from 0.1m (4")
to 7m (23ft)
Batteries
C.A.T: 2 × Alkaline or NimH D-cells
(LR20)
Genny: 4 × Alkaline D-cells (LR20)
Unit weight
C.A.T4: 2.3 kg (including batteries)
Genny4: 2.7 kg (including batteries)
The C.A.T4 and Genny4 with optional accessories have been
designed to locate buried utilities. Do not attempt to use for other
purposes.
C.A.T4 and Genny4 products are manufactured in the U.K. under
ISO9001 certified conditions.
19