Zoeller 40 Serie Instrucciones De Instalación
Zoeller 40 Serie Instrucciones De Instalación

Zoeller 40 Serie Instrucciones De Instalación

Efluentes/sumidero/achique / aguas cloacales

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Notice to installing contractor: Instructions must remain with installation.
Product information presented
here re fl ects con di tions at time
of publication. Consult factory
re gard ing dis crep an cies or
in con sis ten cies.
*Effl uent systems should specify that pumps should not handle solids exceeding three fourths inch (¾") in order to prevent large solids from entering leeching fi elds, mound systems etc.
(Model 49 and 70 Series have 3/8" solids capability, 50, 90, 140, 145/4145, 151, 371 and 372 Series have ½", 130 Series has 5/8", 152,153, and 160/4160/180/4180, 373 Series have
¾".) Where codes permit, sewage pumps can be used for effl uent systems. Nonautomatic pump(s) with external level control recommended for septic tank effl uent applications.
PREINSTALLATION CHECKLIST - ALL IN STAL LA TIONS
1.
Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover nor the motor housing.
2.
Carefully read the literature provided to familiarize yourself with specifi c details regarding in stal la tion and use. These materials should be retained for future reference.
1. Make certain that the receptacle is within the reach of the pump's pow er supply cord. DO NOT
USE AN EXTENSION CORD. Extension cords that are too long or too light do not deliver suffi cient
voltage to the pump motor. But, more important, they could present a safety haz ard if the insulation
were to become damaged or the con nec tion end were to fall into the sump.
2. Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of
proper capacity. A separate branch circuit is rec om mended, sized ac cord ing to the "National
Elec tri cal Code" for the current shown on the pump nameplate.
3. Testing for ground. As a safety measure, each electrical outlet should be checked for ground
using an Underwriters Laboratory Listed circuit analyzer which will indicate if the power, neutral
and ground wires are correctly connected to your outlet. If they are not, call a qualifi ed licensed
electrician.
4. For Added Safety. Pumping and other equipment with a 3-prong grounded plug must be connected
to a 3-prong grounded receptacle. For added safety the receptacle may be protected with a ground-
fault circuit interrupter. When a pump needs to be connected in a watertight junction box, the plug
can be removed and spliced to the supply cable with proper grounding. For added safety this circuit
may be protected by a ground-fault circuit in ter rupt er. The complete in stal la tion must comply with
the National Electrical Code and all applicable local codes and ordinances.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POW ER SOURCE BE FORE
HANDLING. Single phase pumps are sup plied with a 3-prong ground ed plug to help protect you
against the possibility of electrical shock. DO NOT UNDER ANY CIRCUM STANCES RE MOVE THE
GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong grounded receptacle.
If the in stal la tion does not have such a receptacle, it must be changed to the prop er type, wired
and ground ed in ac cor dance with the National Elec tri cal Code and all applicable local codes and
or di nanc es. Three phase pumps require motor starting devices with motor overload pro tec tion. See
FM0486 for duplex in stal la tions. Pumps must be in stalled in ac cor dance with the National Electrical
Code and all ap pli cable local codes and ordinances. Pumps are not to be installed in locations
clas si fi ed as hazardous in accordance with National Electrical Code, ANSI/NFPA 70.
6. "Risk of electrical shock" Do not remove power supply cord and strain relief or connect conduit
directly to the pump.
7. Installation and servicing of electrical circuits and hardware should be performed by a qualifi ed
li censed electrician.
8. Pump installation and servicing should be performed by a qualifi ed person.
9. Risk of electric shock - These pumps have not been investigated for use in swimming pool and
marine areas.
10. According to the state of California (Prop 65), this product contains chemicals known to the state
of California to cause cancer and birth defects or other reproductive harm.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
INSTALLATION INSTRUCTIONS
RECOMMENDED MODELS
EFFLUENT*/SUMP/DEWATERING
49, 50 Series, 70 Series, 98 Series
130 Series, 140/4140, 145/4145 Series, 150 Series, 160/4160 Series
180/4180 Series, 191, 371, 372, 373
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2009 Zoeller Co. All rights reserved.
SEWAGE
211 Series, 264 Series
260 Series, 270/4270 Series
280/4280 Series, 290/4290 Series
1. Check to be sure your power source is capable of handling the voltage re quire ments of the motor,
as indicated on the pump name plate.
2. The installation of automatic pumps with variable level fl oat switch es or nonautomatic pumps using
auxiliary variable level fl oat switches is the re spon si bil i ty of the in stall ing party and care should be
tak en that the tethered fl oat switch will not hang up on the pump apparatus or pit peculiarities and
is secured so that the pump will shut off. It is recommended to use rigid piping and fi ttings and the
pit be 18" or larger in diameter.
3. Information - vent hole purpose. It is necessary that all sub mers ible sump, effl uent, and sewage
pumps capable of handling various sizes of solid waste be of the bottom intake design to reduce
clog ging and seal failures. If a check valve is incorporated in the installation, a vent hole (approx.
3/16") must be drilled in the discharge pipe below the check valve and pit cover to purge the unit
of trapped air. Trapped air is caused by agitation and/or a dry basin. Vent hole should be checked
periodically for clogging. The 50 or 90 Series pumps have a vent lo cated in the pump housing
opposite the fl oat, ad ja cent to a housing lug, but an additional vent hole is recommended. The
vent hole on a High Head application may cause too much turbulence. You may not want to drill
one. If you choose not to drill a vent hole, be sure the pump case and impeller is covered with liquid
before connecting the pipe to the check valve and no inlet carries air to the pump intake. NOTE:
THE HOLE MUST ALSO BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY. Water
stream will be visible from this hole during pump run periods.
4. Pump should be checked frequently for debris and/or build up which may interfere with the fl oat "on"
or "off" position. Repair and service should be performed by Zoeller Pump Company Authorized
Service Station only.
5. Dewatering and effl uent sump pumps are not designed for use in pits handling raw sewage.
6. Maximum operating temperature for standard model pumps must not ex ceed 130°F (54°C). Model
49 max. temperature must not exceed 104ºF (40ºC). The 70 and 211 Series max. temperature must
not exceed 110ºF (43ºC).
7. Pump models 188/4188, 189/4189, and 295/4295 nonautomatic pump must run totally submerged
and CSA certifi ed pumps must be operated submerged with "off - on" level controls.
8. Pump models 266, 267, 268, 137 and 139 must be operated in an upright position. Do not attempt
to start pump when tilted or laying on its side.
9. Do not operate a pump in an ap pli ca tion where the Total Dynamic Head is less than the minimum
Total Dynamic Head listed on the Pump Performance Curves.
10. Model 49 is for indoor use only.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL Standard UL778.
CSA Certifi ed pumps are certifi ed to CSA Standard C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
1
SECTION: 6.10.001
FM0447
Rev. A
0809
Supersedes
0309
visit our web site:
www.zoeller.com
DATE INSTALLED:
MODEL NUMBER:
SEE BELOW FOR
LIST OF CAUTIONS

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Zoeller 40 Serie

  • Página 1 GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong grounded receptacle. or “off” position. Repair and service should be performed by Zoeller Pump Company Authorized If the in stal la tion does not have such a receptacle, it must be changed to the prop er type, wired Service Station only.
  • Página 2: Electrical Precautions

    If the above checklist does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. Service must be performed by Zoeller Authorized Service Stations. Go to www.zoeller.com/zcopump/TechSupport/authsslisting.htm to fi nd the Authorized Service Station in your area.
  • Página 3 & Dewatering only). pipe even with the top of the pump. NOTE: THE HOLE MUST ALSO (14) Install Zoeller Pump Stand (Model 10-2421) under pump to provide a BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY. settling basin. (Effl uent & Dewatering only.) (High Head unit see #3 under “Caution”...
  • Página 4 IMPORTANT NOTICE: Some insurance policies, both commercial and residential, extend coverage for damages incurred by product failure. You will need to have possession of the product to support your claim in most cases. Zoeller Pump Co. will exchange the unit or refund the original purchase price once the claim is settled with the insurer in the case where you need to retain possession of the product to support a damage claim you submit to your insurance company.
  • Página 5: Modelos Recomendados

    AVISO: Las bombas con la marca “UL” y “US” han sido probadas de acuerdo al estándar UL778. Las bombas “aprobadas por CSA” están certifi cadas de acuerdo al estándar CSA C22.2 No. 108. REFIÉRASE A LA GARANTÍA EN LA PÁGINA 2. © Copyright 2009 Zoeller Co. All rights reserved.
  • Página 6: Garantía Limitada

    Si la lista de verifi cación arriba mencionada no revela el problema, consulte con la fábrica. No intente proporcionar algún servicio o desarmar la bomba. Las Estaciones de servicio autorizadas por Zoeller deberán proporcionar dicho servicio. Visite el sitio www.zoeller.com/zcopump/TechSupport/authsslisting.htm para encontrar la estación de servicio autorizada para su zona. © Copyright 2009 Zoeller Co. All rights reserved.
  • Página 7: Instalación Recomendada Para Todas Las Aplicaciones

    3 de la lista de “Precauciones” en la hacerse a través de una caja de conexión hermética Zoeller o un empalme her- página 1.) Se verá un chorro de agua saliendo del agujero durante los períodos mético.
  • Página 8 AVISO IMPORTANTE: Ciertas pólizas de seguro, tanto comerciales como residenciales, extienden la cobertura a los daños causados por la falla del producto. En la mayoría de los casos, usted deberá conservar el producto para respaldar su reclamo. Zoeller Pump Co. reemplazará la unidad o reembolsará el precio de compra original una vez que la compañía de seguros liquide el reclamo, en el caso de que usted necesite conservar el producto para respaldar un reclamo...
  • Página 9 à trois broches mise à la terre. Si le circuit n’est pas équipé d’une telle prise, il de réparation agréé par Zoeller Pump Com pa ny. faut en installer une en respectant les codes électriques nationaux et locaux. Toutes les pompes 5.
  • Página 10: Garantie Limitée

    Si les vérifi cations ci-dessus ne résolvent le problème, consulter l’usine. Ne pas essayer de réparer ou de démonter la pompe. Toutes les réparations doivent être faites par un centre de réparation agréé par Zoeller. Visitez le site Web www.zoeller.com/zcopump/TechSupport/authsslisting.htm pour trouver le centre de service agréé...
  • Página 11: Installation Typique

    Il est possible de fabriquer les supports de fl otteur en utilisant des tuyaux et des raccords standard pour faciliter la dépose en cas de réparation. Les supports de fl ottes sont disponible chez Zoeller tel que décrit au feuillet FM0526 ou peuvent être fabriqué avec de la tuyauterie et des raccords standard.
  • Página 12: Instructions De Branchement Monophasé

    REMARQUE IMPORTANTE. – Certaines polices d’assurance commerciales et résidentielles couvrent les dommages résultant d’une défaillance du produit. Dans la plupart des cas, vous devez être en possession du produit pour déposer une réclamation. Zoeller Pump Co. s’engage à remplacer l’appareil ou à rembourser le prix d’achat original après que l’assureur aura réglé la réclamation dans un cas où vous êtes tenu d’être en possession du produit pour documenter une réclamation soumise à...

Tabla de contenido