READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
TYPICAL INSTALLATIONS
POWER CABLE
CEILING
JOIST
CEILING
MATERIAL
16"-ON-CENTER CEILING JOISTS
Housing mounted directly to joist.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
MODELS 741BR • 741SN • 741WH • 741BRFL • 741WHFL
®
MOUNTING TABS
HOUSING
GRILLE
PAN
GLASS
LIGHT SHADE
WARNING
7. NEVER place a switch where it can be reached from a tub or
shower.
8. Fluorescent models only: Do not use a dimmer switch to con-
trol the light of this unit.
9. This unit must be grounded.
10. This unit is U.L. listed. Type I.C. inherently protected.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for ceiling installation only. This prod-
uct is designed for installation in ceilings up to a 12/12 pitch.
Ductwork must point up. DO NOT MOUNT THIS PRODUCT IN
A WALL.
3. The light fixture assembly must be mounted to the fan housing
assembly included with this product. Do not mount the light
fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
5. Please read specification label on product for further informa-
tion and requirements.
TYPICAL INSTALLATIONS
POWER CABLE
MOUNTING TABS
HOUSING
CEILING
MATERIAL
24"-ON-CENTER CEILING JOISTS
Housing mounted to additional framing.
4" ROUND
DUCT
ADDITIONAL
FRAMING
CEILING
JOIST
GRILLE
GLASS
PAN
LIGHT SHADE
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan 741BR

  • Página 1 MODELS 741BR • 741SN • 741WH • 741BRFL • 741WHFL ® Page 1 DECORATIVE SERIES CEILING VENTILATORS READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- 7. NEVER place a switch where it can be reached from a tub or JURY TO PERSONS, OBSERVE THE FOLLOWING: shower.
  • Página 2: Typical Installations

    MODELS 741BR • 741SN • 741WH • 741BRFL • 741WHFL ® Page 2 TYPICAL INSTALLATIONS INSTALL THE HOUSING (continued) (continued) New Construction 4" ROUND DUCT POWER CABLE MOUNTING HOUSING GRILLE SUSPENDED CEILING GLASS MATERIAL LIGHT SHADE SUSPENDED CEILINGS 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
  • Página 3: Connect The Wiring

    MODELS 741BR • 741SN • 741WH • 741BRFL • 741WHFL ® Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM L I G H T R E D B L U W H T L I G H T...
  • Página 4: Service Parts

    OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 97014922 Housing Assembly During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. 99523699 Light Fixture Assembly (741BR) THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES.
  • Página 5: Ventiladores De Cielo Raso Serie Decorativa

    MODELOS MODELS 741BR • 741SN • 741WH • 741BRFL • 741WHFL ® Página 5 Page 5 VENTILADORES DE CIELO RASO SERIE DECORATIVA LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA ADVERTENCIA 5. Cuando corte o perfore la pared o el cielo raso, tenga cuidado PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉC-...
  • Página 6: Instalación De La Cubierta

    MODELOS MODELS 741BR • 741SN • 741WH • 741BRFL • 741WHFL ® Page 6 Página 6 INSTALACIÓN DE LA INSTALACIONES TÍPICAS CUBIERTA (continuación) (continuación) Construcción nueva CONDUCTO REDONDO DE 4" (10.2 cm) CABLE DE ALIMENTACIÓN ALETA DE CUBIERTA MONTAJE PLATILLO...
  • Página 7: Construcción Existente

    MODELOS MODELS 741BR • 741SN • 741WH • 741BRFL • 741WHFL ® Página 7 Page 7 INSTALACIÓN DE LA CONEXIÓN ELÉCTRICA CUBIERTA (continuación) DIAGRAMA ELÉCTRICO C O M M . R O J O A Z U L B L A N C O L A M P .
  • Página 8: Uso Y Cuidado

    98008868 Placa de las Alambres TIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR. Durante este período de un año, Broan-NuTone reparará o cambiará, a su opción y sin cobro, cualquier producto 97014185 Conjunto Conector Registro/Ducto o pieza que se encuentre defectuosa bajo uso y servicio normal.

Este manual también es adecuado para:

741sn741wh741brfl741whfl

Tabla de contenido