Connect Gas Supply
The gas inlet to the unit is located at the right rear of rough-in box. After installing
a gas shut-off valve in an easily accessible location under the unit, install the pres-
sure regulator (supplied) to manifold pipe using Teflon tape on threads of manifold
pipe. To prevent possible damage to the gas pressure regulator, install it after the
rough-in box is in its permanent position.
Opening for Gas
Connection and
Electrical Cord
CAUTION:
Do not attempt any adjustment of the pressure regulator,
except conversion to propane.
Connect the gas supply line to the unit pressure regulator using a 1/2" flex gas line
connector between wall shut-off valve and pressure regulator (see complete pro-
cedure in Figure 6.)
Pressure
Regulator
Shows
Direction of
Gas Flow
Secure regulator to cooktop gas inlet using approved Teflon tape. Turn to hand
tighten plus 1/4 turn, not exceeding 1 turn for alignment.
Check supply line connections for leaks using a soap solution. Do not use a flame
of any sort.
1) Turn on gas.
2. Apply a non-corrosive leak detection fluid to all joints and fittings in the gas
connection between the shut-off valve and the range. Include gas fittings and
joints in the range if connections may have been disturbed during installation.
Bubbles appearing around fittings and connections indicate a leak.
3. If a leak appears, turn off supply line gas shut-off valve and tighten connec-
tions.
4. Retest for leaks by turning on the supply line gas shut-off valve. When leak
check is complete (no bubbles appear), test is complete.
5. Wipe off all detection fluid residue.
C of Cutout
L
for 30" models - 12-15/16" (312.8 mm)
for 36" models - 15-15/16" (389 mm)
for 45" models - 20-3/8" (30 mm)
Figure 5: Rough-in Box Area
Rough-in Box
1/2"
Female Pipe
Threads
Supply Cord
120 V
C of Wall
L
Receptacle
Flex Gas Line
Gas Shut-Off Valve
Cabinet Floor
Gas Stubout
Figure 6: Gas and Electrical Location
English 7