Included in the
package
Refer to Fig. 1

Installation

LED's

Refer to Fig. 3
SafeLine LYRA manual.indd 15
SafeLine LYRA manual.indd 15

Included parts:

1.
LYRA main unit
2.
USB wall charger
3.
USB power cable
4.
Door sensor (magnetometer)
Door sensor
Place the external door sensor as close as possible to the lift door
machine for best results. Best placement depends on the door
type, see Fig. 4 for reference.
Connect the USB cable to the main unit (Fig. 5). The main unit and
door sensor must be within reach of each other (the door sensor
cable length is 2 meter, if longer cable is needed a standard 2-3
meter USB extension cable can be used).
One additional door sensor can be ordered with the article number
*LYRA-DS. The second door sensor can used when there are two
door openings.
Main unit
Mount the SafeLine LYRA main unit on top of the lift car. Fasten the
unit with two screws (Fig. 2).
Connect the USB charging cable to the LYRA unit and the wall
charger and then connect the wall charger to a power outlet (Fig.
5).
Installation
For the final part of the installation, please download the LYNX app
from Google Play or Apple App Store.
LED 1 indicates system status
Flashing green
LED 2 indicates data
Continuous yellow
Flashing yellow
LED 3 indicates temperature
Continuous red
Light off
LED 4 indicates the power supply status
Continuous green
Light off
15
System OK.
Unit is booting.
Data is transmitting.
Unit is not yet in operating
temperature.
Temperature is stable.
Power supply OK.
No power supply.
2020-06-02 15:05