ENGLISH
Effect channel explained
Ramp up:
Ramp down:
Ramp up-down:
Random flash:
Lightning:
Spikes:
Operation via optional BT-STR4 remote:
Connect the BT-STR4 remote to one or more strobes as shown on the picture
Connect the device to the mains
Set the channel mode (ChMd) on the 1
Now you can use the BT-STR4 remote to control the strobes, see the instructions in the user manual of the
remote for further instructions.
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
BRITEQ
®
006 - 255
From slow to fast
No effect
000 - 005
Ramp up
006 - 042
Ramp down
043 - 085
4
086 – 128
Ramp up / down
129 - 171
Random
Lightning
172 - 214
Spikes
215 - 255
light intensity gradually increases, followed by a blackout
light flashes to full intensity, followed by a gradual fadeout.
light intensity gradually increases and decreases.
light flashes randomly with variable rate and intensity.
No sync between units.
flashes simulate lightning.
In between flashes the lamp remains lit at low output.
st
unit to rEM1, 2
7/42
Effect channel
nd
unit to rEM2, ...
USER MANUAL