4.4. Positioning of the adjustment sleeve
With the F-senso pull-in measurement device, it is possible to take tolerances
between the spindle and tool into consideration.
You should measure with the adjusting sleeve in the position shown in the illustration
(see circular marking on the right picture) if there is no wear on the tool clamping
system, spindle shaft and clamp set. Wear can be taken into consideration for the
measurement by adjusting the adjusting sleeve.
At the beginning, set the adjustment sleeve to the desired position.
One grid mark on the adjusting sleeve corresponds to an axial displacement of
0.1 mm.
The adjusting sleeve must be snapped into place exactly after each
adjustment.
Turning the adjustment sleeve in the "+" direction means lengthening the pull-
in element on the adapter; turning in the "-" direction means shortening it.
(In other words, displacement of the end face towards the taper of the
adapter).
Heinrich-Röhm-Str. 50, 89567 Sontheim/Brenz., GERMANY, Tel. (49)7325/16-0