Troubleshooting

8.3 Replacing the stripping blades

Potential risk of fatality due to electric
shock
When working on the inside of the machine,
non-insulated parts may be touched.
► Switch the machine off.
► Remove the compressed air hose from the
compressed air source.
► Pull the power plug.
► Open the front plate and place it down
carefully.
Risk of injury posed by sharp blades
► Use forceps to change the blades.
► Dispose of the removed blades in a sepa-
rate container.
All present blades must be replaced each time
the knife is changed.
1
Figure 8.1 Stripping unit
► Remove both eccentrics (1) (2.5 mm Allen key).
► Release the fixing screws (2) (2.0 mm Allen key) and
remove the cover.
48
WARNING
CAUTION
2
► Replace all present blades with new ones.
L, LS
Figure 8.2 Blade alignment
► L and LS: Assemble each blade pair so that the bevelled
edges point outwards (marked in red in figure 8.2).
Place both blade pairs in the holder.
► LZ: inset the blades so that the bevelled edges point to-
ward each other.
► Fix the cover back on.
► Fix both eccentrics so that they are in position "0".
► Conduct a stripping test (see section 5.5).

8.4 Replacing fuses

► Make sure that the machine is switched off.
► Remove the power plug.
Figure 8.3 Opening the fuse compartment
► Lever the fuse compartment (1) out of the mains filter
unit using a slotted screwdriver.
► Replace both fuses with new ones (2 x T2AH250V).
► Put the fuse compartment back into the mains filter unit.
LZ
1
2518100000/03/06.2017