Technical Data

Battery Charger
Article number
Output voltage
Charging current
Allowable charging temperature
range
Charging time for battery capacity,
approx.
– 1.3 Ah
– 2.6 Ah
– 3.0 Ah
– 4.5 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01/2003
Protection class
Please observe the article number on the type plate of your battery
charger. The trade names of individual battery chargers may vary.
Operation

Starting Operation

Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the mains plug of
the battery charger is plugged into the socket outlet and the
battery 1 is inserted into the charging compartment 2.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Meaning of the Indication Elements
Flashing Green Battery Charge Indicator 3
The rapid-charging procedure is signalled
by a flashing green battery charge indica-
tor 3.
Bosch Power Tools
During the charging procedure, the three green charge-con-
trol indicators 5 of the battery light up one after the other
and briefly go out. The battery is fully charged when the three
green indicators light up continuously. After approx.
5 minutes after the battery has been fully charged, the three
green indicators go out again.
Note: The rapid-charging procedure is only possible when the
battery temperature is within the allowable charging temper-
ature range, see section "Technical Data".
AL 3640 CV
Professional
Continuous Lighting of the Green Battery Charge Indica-
tor 3
2 607 225 ...
V
36
A
4.0
Additionally, a signal tone sounds for approx. 2 seconds,
°C
0 – 45
which acoustically indicates that the battery is fully charged.
Afterwards, the battery can be removed for immediate use.
min
15 (75%)
When the battery is not inserted, continuous lighting of the
min
45 (100%)
battery charge indicator 3 indicates that the mains plug is in-
min
30 (75%)
serted in the socket and that the battery charger is ready for
min
60 (100%)
operation.
min
35 (75%)
Continuous Lighting of the Red Battery Charge Indicator 4
min
75 (100%)
min
55 (75%)
min
90 (100%)
10 – 30
section "Technical Data". As soon as the allowable charging
kg
1.0
temperature range is reached, the battery charger automati-
/ II
cally switches to rapid charging.
When the red temperature control indicator 6 lights up
when placing the battery into the charger, the temperature of
the battery is not within the charge-temperature range (see
section "Technical Data"). The battery cannot be charged un-
til after the allowable operating temperature range has been
reached.
Flashing Red Battery Charge Indicator 4
Troubleshooting
Measures
Cause
Flashing red battery charge indicator 4
No charging procedure possible
Battery not (properly)
inserted
Battery contacts
contaminated
Battery defective
English | 7
Continuous lighting of the green battery
charge indicator 3 indicates that the bat-
tery is fully charged.
Continuous lighting of the red battery
charge indicator 4 indicates that the tem-
perature of the battery is not within the al-
lowable charging temperature range, see
A flashing red battery charge indicator 4
indicates a different malfunction of the
charging procedure, see section "Trouble-
shooting – Causes and Corrective
Measures".
Causes and Corrective
Corrective Measure
Properly insert battery into
battery charger
Clean the battery contacts
(e.g. by inserting and remov-
ing the battery several times)
or replace the battery
Replace the battery
1 609 929 X52 | (27.7.11)