Technical Data - Milwaukee DWSE 4000 Q Manual Original

Ocultar thumbs Ver también para DWSE 4000 Q:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13

TECHNICAL DATA

Production code......................................................................
Rated input .............................................................................
Output .....................................................................................
No-load speed ........................................................................
Self-drill screws up to max......................................................
Allen screws (key width) .........................................................
Dry wall screws up to max. .....................................................
Setting range of depth gauge .................................................
Universal reception .................................................................
Weight according EPTA-Procedure 01/2003 ..........................
Noise information
Measured values determined according to EN 60745.
Typically the A-weighted sound pressure level of the tool is:
Sound pressure level (Uncertainty K=3dB(A)).....................
Sound power level (Uncertainty K=3dB(A)) .........................
Wear ear protectors!
Vibration information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
h
Screwing ..............................................................................
Uncertainty K .......................................................................
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may signifi cantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may signifi cantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SCREWDRIVER SAFETY WARNINGS
Hold power tool by insulated gripping surfaces, when
performing an operation where the fasteners may
contact hidden wiring or its own cord. Fasteners
contacting a "live" wire may make exposed metal parts of
the power tool "live" and could give the operator an electric
shock.
Wear ear protectors when impact drilling. Exposure to
noise can cause hearing loss.
ADDITIONAL SAFETY AND WORKING INSTRUCTIONS
Use protective equipment. Always wear safety glasses when
working with the machine. The use of protective clothing is
recommended, such as dust mask, protective gloves, sturdy
non-slip footwear, helmet and ear defenders.
The dust produced when using this tool may be harmful to
health. Do not inhale the dust. Wear a suitable dust
protection mask.
Do not machine any materials that present a danger to
health (e.g. asbestos).
Switch the device off immediately if the insertion tool stalls!
Do not switch the device on again while the insertion tool is
stalled, as doing so could trigger a sudden recoil with a high
reactive force. Determine why the insertion tool stalled and
rectify this, paying heed to the safety instructions.
The possible causes may be:
• it is tilted in the workpiece to be machined
• it has pierced through the material to be machined
16
ENGLISH
DWSE 4000 Q
TKSE 2500 Q
..................... 7520 30 02... ............. 3845 16 02...
...000001-999999
...000001-999999
.........................725 W ...........................725 W
.........................340 W ...........................340 W
....................0-4000 min
..................0-2500 min
-1
-1
..............................- ...............................6,5 mm
..............................- ................................10 mm
.............................4 mm
.......................± 3,8 mm ......................± 3,8 mm
.........................1/4" ..............................1/4"
..........................1,3 kg ............................1,4 kg
...........................98 dB (A) ......................98 dB (A)
.........................109 dB (A) ....................109 dB (A)
..........................2,9 m/s
.........................2,9 m/s
2
2
..........................1,5 m/s
.........................1,5 m/s
2
2
• the power tool is overloaded
Do not reach into the machine while it is running.
The insertion tool may become hot during use.
WARNING! Danger of burns
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the machine
is running.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
When working in walls ceiling, or fl oor, take care to avoid
electric cables and gas or waterpipes.
Clamp your workpiece with a clamping device. Unclamped
workpieces can cause severe injury and damage.
Always disconnect the plug from the socket before carrying
out any work on the machine.
SPECIFIED CONDITIONS OF USE
The screwdriver is suited for setting dry wall screws when
fi xing gypsum plaster boards to wood furring or metal
furring.
Do not use this product in any other way as stated for
normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product
described under "Technical Data" fulfi lls all the relevant
regulations and the directives 2011/65/EU (RoHs), 2014/30/
EU, 2006/42/EC, and the following harmonized standards
have been used:
EN 60745-1:2009 + A11:2010
EN 60745-2-2:2010
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:1997+A1:2001+A2:2008
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 50581:2012
Winnenden, 2016-03-29
Alexander Krug
Managing Director
Authorized to compile the technical fi le
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
MAINS CONNECTION
Appliances used at many different locations including wet
room and open air must be connected via a residual current
device (FI, RCD, PRCD) of 30mA or less.
Connect only to single-phase AC current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
Make sure the machine is switched off before plugging in.
This is a device for professional use which may slightly
exceed the guide values for current harmonics when it is
connected to the public low voltage mains supply. You
should therefore contact your energy supply company
before you connect the device to the public low voltage
mains supply.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
Important note! If the carbon brushes are worn, in addition
to exchanging the brushes the tool should be sent to
after-sales service. This will ensure long service life and top
performance.
If the supply cord of this appliance is damaged, it must only
be replaced by a repair shop appointed by the manufacturer,
to avoid hazardous situations.
Use only Milwaukee accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our Milwaukee service
agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket
before carrying out any work on the machine.
Please read the instructions carefully before
starting the machine.
Do not dispose of electric tools together with
household waste material.
Electric tools and electronic equipment that
have reached the end of their life must be
collected separately and returned to an
environmentally compatible recycling facility.
Check with your local authority or retailer for
recycling advice and collection point.
Class II tool, tool in which protection against
electric shock does not rely on basic
insulation only, but in which additional safety
precautions, such as double insulation or
reinforced insulation, are provided.
There being no provision for protective
earthing or reliance upon installation
conditions.
European Conformity Mark
National mark of conformity Ukraine
EurAsian Conformity Mark.
ENGLISH
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tkse 2500 q

Tabla de contenido