4. Route the flexible electrical supply conduit from the oven to the junction box
through a UL listed or CSA approved conduit connector.
5. Tighten screws on conduit connector.
3-WIRE CONNECTION (GROUNDED NEUTRAL) - U.S.A. ONLY
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and recreational
vehicles, or in an area where local codes prohibit grounding through the
neutral conductor. For installations where grounding through the
neutral conductor is prohibited, see the Ungrounded Neutral graphic.
Use grounding terminal or lead to ground unit.
Connect neutral terminal or lead to branch circuit neutral in usual
manner.
Failure to do so could result in death, re or electric shock.
3-Wire Cable from Home Power Supply
IMPORTANT: Use the 3-wire cable from home power supply where local codes
permit a 3-wire connection.
1. Disconnect power.
a
Junction Box
b
Black Wires
c
Neutral (White)
Wires
12
WARNING
Electrical Shock Hazard
Grounded Neutral
a
b
c
d
e
d
Ground (Green or
Bare) Wire
e
Cable from Oven
f
UL Listed Conduit
Connector
i
h
g
f
g
Red Wires
h
UL Listed Wire Connectors
i
House Electrical Supply