Operating Instructions
Mounting
The instrument is designed as built-in counter for in-door use. Please refer
to the following drawings for the cutout measures, the cutout size, as well
as the mounting accessories.
60.8
48
Cutout size
55 min.
1 Shove instrument with gasket from the front inside the cutout.
2 Shove clamping frame from the back over enclosure and fasten.
18.5
Adapter plate Z 118.033
3
45 +0.6
108
clamping frame
60 -0.2
8.3
48.7 -0.6
45.45 ±0.25
4.3
R1
NE131
Packing
1-6
7
Counter-
sinking
Af4 DIN 74
9