PUMP MODULE
Accessories for eco•wash system
2.3
A
RS485
DAPTING
ATTENTION: Before carrying out maintenance on the appliance, always disconnect the power
supply.
To be done only if the last module making up the system is a pump module.
Open the last pump module.
Move the jumper JP5 on the circuit to the 120 Ohm position.
Close the module again
3.0
OPERATION
T
HE
pump can be primed manually or by remote control (via PC programs or standard console): In any event, the
pump can only be primed after the system has been configured through the Aquaware Configurator program.
3.1
M
ANUAL PRIMING
By pressing the button at the top of the pump, it will run at the set speed for one minute.
The pump can be stopped by pressing the button again.
4.0
TROUBLESHOOTING
The pump module does not switch-
on
The pump is not functioning
ADSP7000610
Make sure the green connector is inserted properly.
On the circuit, verify there are no disconnected wires on the motor clamps of the pump.
Verify the motor is not locked.
Verify at least one red LED on the circuit is on.
rev. 1.2
20/02/2014
OPERATION
ENGLISH
9/26