Electric Connections - PSA ZODIAC Heat line+ 20 Manual De Instalación Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
House heating
circulation pump
House heating
3 Way valve
Aquastat
Caution! Connections of primary circuit shall be
realised before any valve or pump.

4.2 Electric connections

• The single-phase electrical supply (230V-50Hz) of the exchanger must come from a protection and
switching device (not supplied) complying with the standards and regulations in force in the country
where it is installed (in France, refer to standard NF C 15100).
• use the supply cable delivered with the appliance: 2 poles + Earth 10/16 A in 3G1 (section 1 mm²).
Do not admit any long extension or multisocket connection.
Remark: Plan for a socket to connect the supply cable delivered with the appliance.
• Electrical protection: this current socket must have a 5 A fuse switch with, upstream, a 30 mA
differential circuit breaker (calibre > than 5 A), or an independent 30 mA circuit breaker (calibre 5 A)
upstream.
• use a 3G1 wire (1 mm² section) if you wish to control a complementary pump (fig. 1), an electric
valve (fig. 2 and 3) or a boiler (fig. 4) to provide power to the primary circuit of the exchanger. This
function is carried out via the dry contact without polarity "normally open at rest" (Imax 5A at 250 Vac
50-60hZ) available on the regulator terminals 19-20.
C: complementary pump
CH: existing boiler
F: fuse
The elements: C - CH - F - KA1 - V' - V'' are not supplied with this device.
Notice:
• electric cables shall be fixed,
• the wire connected to terminals 19-20 must go through the additional discharger 'grommet' (supplied) which
should be installed on the base of the box.
HYDRAULIC CONNECTIONS
TO RADIATORS
Valves
Pressure valve
Expansion vessel
Gas or Fuel-oil boiler
KA1: control relay
V': 3 port valve with mechanical return
V'': 3 port motorized valve with movement in two directions
5
Pool water filtration circuit
Primary circuit
House heating circuit
Automatic air bleed
Circulating pump
E
Pump
Filter
Heat Line
Check valve
S
Water treatment
+
(heat exchanger)
E = From pool
S = To pool
Ph: phase
N: neutral
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zodiac heat line+ 40Zodiac heat line+ 70

Tabla de contenido