1.0
Introduction
These instructions cover the installation and calibration of the sheet Tension Indicator System
from ALTEC. The tension indicators are designed to be used with the load cells ALTEC or CMC.
Refer to manual for installing them.
2.0
Configuration
The indicators can be supplied with DIN 1/8 case for mounting on front panels or open panels for
mounting on DIN rail.
3.0
Specifications
Power Supply
Excitation for load cell
Input sensitivity
Display
Reading refreshment:
Analog outputs
Operating temperature
Size
* Selected internally by moving jumper.
4.0
Operation Principle
The tension reading on a sheet is made by sensing, via load cells with strain gages, the force
caused on the sensor roll. The electric signal is registered in the indicator as the total tension.
www.altec.com.br
: 110/220 Vac - 50/60 Hz selected by fixed jumper.
: 5 or 10 Vdc *
: 1 mV (min.) to 2 V (max.) *
: Red LED indication, 3 1/2 digits.
: 2.5 times per second, with display reading dampening*, without affecting
the output signal.
: 0 -10 Vdc 2 mA (max.) or 4 - 20 mA (250Ω)*
: 0 - 60ºC.
: DIN 1/8
EMBRACING
ANGLE
SHEET
RESULTANT
TENSION INDICATOR MODEL EI-185
SIGNAL TRANSMITTER MODEL EI-264
21