FOB OPERATION:
Single fob also sold separately: #44485001
NOTE:
The fob has a maximum operating range of 75'.
The fob may be paired with only one lock.
The lock may be paired with a maximum of 10 fobs.
It is recommended that you change the coin cell battery in the fob annually.
The fob WILL retain all current lock pairings while changing the battery.
The fob is not an access credential. It is only used to activate/deactivate Lockdown Mode.
Fob Button Operation:
While the 75 Function is UNLOCKED in NORMAL Mode
Button Press
2 Second
Fob Press
While the 75 Function is LOCKED in NORMAL Mode
Button Press
2 Second
Fob Press
While the 75 Function is in LOCKDOWN Mode
Button Press
20 Second
Fob Press
Press and
Release
Safe School
Button*
*See SAFE SCHOOL BUTTON OPERATION
NOTE:
When the 75 Function is in Normal Mode, it operates as a standard
classroom lock. Construction Access, Manual Lock Programming, and Proximity Credential
functions all operate the same as they do for a standard classroom/storeroom lock; however,
when the 75 Function is in Lockdown Mode, only a pass-through function may gain temporary
access. In this state, any other credential function makes the Schlage button blink red
(12 times) and the door will not unlock.
Credential Functions
Normal
A normal credential unlocks the door for a specified time
Toggle
A toggle credential unlocks a door until it is locked again by a toggle credential
Freeze
A freeze credential disables the credential reader until a freeze credential enables it
Pass-
A pass-through credential will momentarily unlock a door that is in Lockdown Mode
Through
or currently locked
Resulting State
Lockdown Mode
Resulting State
Lockdown Mode
Resulting State
Normal Mode
Normal Mode
Successful Function Change Indicator
Red LED Blinks 4 Times and Continues to
Blink On/Off at a ¹⁄₂ Second Interval
Successful Function Change Indicator
Red LED Blinks 4 Times and Continues to
Blink On/Off at a ¹⁄₂ Second Interval
Successful Function Change Indicator
Green LED Blinks 4 Times
Green LED Blinks 4 Times