3.7.
Connection of thermal oil (only for thermal oil models)
The installation of the dryer with thermal oil heating must comply with current standard
regulations.
The customer must connect the thermal oil to the machine to the foreseen connection through a
valve (we recommend a 3-way valve to favour oil circulation in the facility, with a bypass to the
machine when thermal oil supply is not necessary).
The machine supplies a signal of 230V active when an inlet of oil is required.
The measurements of the power supply and evacuation valve must correspond to the adequate,
flow and pressure and temperature according to the machine's specifications. The diameter
must not be smaller than the inlet and outlet flanges of the dryer.
3
Tumble dryers batteries normally work with thermal fluid flows ranging from 7 m
/h for the
3
DTA/DTP-45 and 10 m
/h. for the DTA/DTP-60/80, and an inlet temperature of around 180 ºC.
CAUTION: USE APPROPRIATE COMPONENTS FOR THE FLOW AND TEMPERATURE
WORKED WITH
76